Hampton Inn & Suites Edmonton West - Kool Pool

18304 100 Avenue NW Edmonton AB T5S 2V2 · Aquatic Facility

Inspection summary

Hampton Inn & Suites Edmonton West - Kool Pool has been inspected 13 times by Alberta Health Services (Environmental Public Health) since December 20, 2023. The most recent inspection, on June 12, 2026, found no infractions.

6 of 13 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 7 times across 7 separate inspections, most recently on June 11, 2026. For example: Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 2 times on June 26, 2024. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

13 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • Three tests were conducted with 3 different samples. The free chlorine was measure at or above the maximum range (6 ppm) of the Pool Lab 2.0 test kit. Corrective Action:- Operator conducted manual test with Taylor test kit. Free chlorine was measured greater or equal than 6 ppm.- Operator adjusted pool chemicals to bring chlorine down.- Advised operator to test chlorine after a couple hours (at least one turnover) to ensure free chlorine is within required levels, and notify me once in compliance.
  3. Monitoring Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Temperature of the Kool pool was 30.6C. Please check off pool greater or equal to 30C on the weekly water sample requisition form or lower the temperature to less than 30C
  5. Monitoring Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Temperature of the Kool pool was 30.6C. Please check off pool greater or equal to 30C on the weekly water sample requisition form or lower the temperature to less than 30C
  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on October 29, 2024 was unsatisfactory: HPC 100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  8. Risk Management Inspection

    0 infractions

  9. Monitoring Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The water was tested 3 times for pH reading.1st reading (from basin): pH 6.52nd reading (from basin): pH 6.53rd reading (from controller): pH 6.5-The pool was closed by the operator to make adjustments. Closure signage was put up near the pool deck. -After making the adjustments. pH was tested again by both PHIT and the operator.PHIT's reading using WATER-I.D. GMBH pool kit: pH= 6.8 ppmOperator's reading using Taylor technologies pool kit: pH= 6.8 ppmThe pool was re-opened and the closure signage was removed.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity: 00 ppmThe operator adjusted the alkalinity during inspection onsite. The operator tested total alkalinity 20 minutes after making adjustments and it was measured as 64ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was discrepancy in the values obtained from the automated feeder controller pH= 7.06 (Set point: 7.20) and the values obtained by manual testing pH=6.5The operator was advised to clean and maintain the probe sensors of the controller to get accurate readings.
  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological samples collected 2024-05-07 was unsatisfactory- HPC 230 cfu/mlTake all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  11. Risk Management Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological samples collected 2024-05-07 was unsatisfactory- HPC 200 cfu/mlTake all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  13. Monitoring Inspection

    0 infractions