Magma Massage Healing Haven has been inspected 2 times by Alberta Health Services (Environmental Public Health) since September 28, 2026. The most recent inspection, on October 2, 2026, recorded 1 infraction.

None of the 2 inspections on record were free of infractions. In the past 12 months there were 2 inspections with 5 infractions recorded. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 3 times across 2 separate inspections, most recently on October 2, 2026. For example: Is reusable equipment disinfected properly?

  • Permits, records and postingLower risk

    Operating permits, client records, sterilization logs and required signage. Client records matter because they let health officials contact people if an infection is linked to the business.

    Recorded once on September 28, 2026. For example: Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded once on September 28, 2026. For example: Are sinks accessible and used appropriately for the personal services provided?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

2 inspections

  1. Risk Management Inspection

    1 infraction

    • 20. Is reusable equipment disinfected properly?
      • HydraFacial detachable reusable heads were not being properly disinfected. These are non-critical tools and must be disinfected using a low- or intermediate-level disinfectant. Ensure that after thoroughly washing them with soap and water, all detachable HydraFacial heads are fully immersed in the PREEmpt RTU disinfectant available at the facility, following the manufacturer's recommended contact time.Corrective Actions Taken:- Reusable semi-critical items will no longer be used at the facility.
  2. Initial Inspection

    4 infractions

    • 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
      • There was no skin cleanser or antiseptic product available at the time of inspection. The operator reported that PurKlenz antiseptic cleanser is expected to arrive on October 1, 2026.Do not provide services requiring skin cleansing or antisepsis until the product is available or use an appropriate alternative in the interim.
    • 20. Is reusable equipment disinfected properly?
      • Re-usable extraction loops and tweezers were observed during the inspection (semi-critical tools), which were not properly cleaned and disinfected between the clients:a. No high-level disinfectant was available for disinfection, as required. b. No designated reprocessing sink was available - the only available sink was a mobile sink.Reusable extractors and tweezers were discarded during the inspection.Discussed with the operator that a mobile sink cannot be used for the reprocessing of semi-critical tools, and that a sink located in a washroom is also not acceptable for this purpose. In addition, semi-critical tools must be reprocessed using an approved high-level disinfectant, such as PREEmpt CS20 or PREEmpt HLD5.
    • 20. Is reusable equipment disinfected properly?
      • HydraFacial detachable reusable heads were not being properly disinfected. These are non-critical tools and must be disinfected using a low- or intermediate-level disinfectant. Ensure that after thoroughly washing them with soap and water, all detachable HydraFacial heads are fully immersed in the PREEmpt RTU disinfectant available at the facility, following the manufacturer's recommended contact time.
    • 31. Are sinks accessible and used appropriately for the personal services provided?
      • A mobile sink was being used to reprocess semi-critical reusable equipment, including comedone extractors and tweezers.