Noora's Beauty Aesthetics and Spa

14 676 Monarch Ave, Ajax ON L1S 4S2 · Know Before You Go Inspections

2 inspections

  1. Routine

    4 infractions

    • All reusable, single-use disposable items and/or equipment are of durable construction, in good repair and maintained as per manufacturer’s instructions
      • Fail to provide reusable, single-use disposable items and/or equipment in good repair. Operator/PSW must provide reusable single-use, disposable items and/or equipment in good repair.
    • Approved disinfectants are prepared and used appropriately, and records maintained
      • Fail to fully immerse items in the disinfectant for the appropriate contact time. Operator/PSW must fully immerse items in the disinfectant for the appropriate contact time.
    • All reusable items and/or equipment cleaned and then disinfected or sterilized, as applicable
      • Fail to thoroughly clean reusable items and/or equipment using a detergent solution and a brush before disinfection or sterilization. Operator/PSW must thoroughly clean reusable items and/or equipment using a detergent solution and a brush before disinfection or sterilization.
      • Fail to disinfect non-porous foot files with high-level disinfectant after each use Operator/PSW must disinfect non-porous foot files with high-level disinfectant after each use
    • All items that cannot be cleaned, disinfected or sterilized must be single-use disposable
      • Fail to discard single-use disposable items and/or items that cannot be readily cleaned and disinfected or sterilized immediately after each use or when contaminated (e.g. pedicure razor blades). Operator/PSW must discard single-use disposable items and/or items that cannot be readily cleaned and disinfected or sterilized immediately after each use or when contaminated (e.g. pedicure razor blades).
  2. Routine

    4 infractions

    • Work and contact surfaces smooth, non-absorbent and easily cleanable
      • Fail to provide fixture and/or furniture in good repair, easily cleanable, smooth and/or impermeable. Operator/PSW must provide fixture and/or furniture in good repair, easily cleanable, smooth and/or impermeable.
    • For invasive services an explanation of the procedure, associated risks and appropriate aftercare are provided to clients
      • For electrolysis and laser hair removal, aftercare instructions may include, but are not limited to: Direction to clean hands immediately before touching the site; expected healing time of the site; a description of possible complications and their signs and symptoms; advice on how to deal with slight redness, pain or swelling; a recommendation to consult with a physician within 24 hours if any signs of infection develop following the procedure; ointment or astringent may be applied to soothe the skin.
    • Approved disinfectants are prepared and used appropriately, and records maintained
      • Fail to maintain disinfectant at appropriate strength. Operator/PSW must maintain disinfectant at appropriate strength.
      • Fail to prepare, maintain and discard solution according to the manufacturer’s instructions (e.g. expired products). Operator/PSW must prepare, maintain and discard solutions according to the manufacturer's instructions (e.g. expired products).
      • Fail to provide and use low and intermediate-level disinfectants with a Health Canada drug identification number (DIN) or natural product number (NPN). Operator/PSW must provide and use low and intermediate-level disinfectants with a Health Canada drug identification number (DIN) or natural product number (NPN).
    • All reusable items and/or equipment cleaned and then disinfected or sterilized as applicable
      • Fail to disinfect reusable items and/or equipment after each use with high-level disinfectant (e.g. microdermabrasion tips/device). Operator/PSW must disinfect reusable items and/or equipment after each use with high-level disinfectant (e.g. microdermabrasion tips/device).