Park Inn by Radisson
555 Cochrane Drive, Markham, ON L3R 8E3 · Class B, Whirlpool/Spa
12 inspections
- Compliance Inspection
1 infraction
- All components of the facility maintained in proper working order
- Fail to ensure all components of the facility unit are maintained in proper working order
- All components of the facility maintained in proper working order
- Compliance Inspection
1 infraction
- All components of the facility maintained in proper working order
- Fail to ensure all components of the facility unit are maintained in proper working order
- All components of the facility maintained in proper working order
- Compliance Inspection
1 infraction
- pH is within required range
- Fail to maintain pH within range of 7.2 to 7.8
- pH is within required range
- Re-inspection
0 infractions
- Compliance Inspection
2 infractions
- Total bromine residual is within required range
- Fail to maintain total bromine residual between 5 - 10 ppm (Spa, Wading Pool, Hot Water Pool)
- Facility kept in safe and sanitary condition
- Fail to maintain all surfaces of the deck and walls free from potential hazards
- Total bromine residual is within required range
- Compliance Inspection
0 infractions
- Re-inspection
0 infractions
- Compliance Inspection
4 infractions
- Total alkalinity is within required range
- Fail to maintain total alkalinity within range of 60 mg/L to 180 mg/L
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Fail to maintain ORP value between 600-900 mV
- Spa water heater equipped with an operational tamper-proof upper limit cut-off switch
- Fail to ensure upper limit cut-off switch limits maximum temperature of spa water to 40ºC (104 F)
- Depth markings present in appropriate locations
- Fail to display markings in figures not less than 100 millimeters high setting out water depth
- Total alkalinity is within required range
- Re-inspection
0 infractions
- Compliance Inspection
2 infractions
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Fail to maintain ORP value between 600-900 mV
- Hydro-massage jet fittings equipped with timing device
- Fail to ensure timing device can be set to 15 minute maximum
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Re-inspection
3 infractions
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Fail to maintain ORP value between 600-900 mV
- Facility conducts required tests at appropriate intervals, as required
- Fail to manually test TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa) 30 minutes prior to opening
- Daily records completed and signed
- Fail to record TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa) 30 minutes before opening the facility
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Compliance Inspection
10 infractions
- Total alkalinity is within range of 80 mg/L to 120 mg/L
- Fail to maintain total alkalinity within range of 80 mg/L to 120 mg/L
- pH is within range of 7.2 to 7.8
- Fail to maintain pH within range of 7.2 to 7.8
- Total bromine residual is within required range
- Fail to maintain total bromine residual between 5 - 10 mg/L
- Fail to maintain total bromine residual of pool water between 2 - 4 mg/L
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Fail to maintain ORP value between 600-900 mV
- Facility conducts required tests at appropriate intervals, as required
- Fail to manually test TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa) 30 minutes prior to opening
- Water clarity is satisfactory
- Fail to ensure pool water clear enough to permit black disc at deepest point to be clearly visible from a point on the deck 9 meters away
- Daily records completed and signed
- Fail to record TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa) 30 minutes before opening the facility
- All components of the facility maintained in proper working order
- Fail to ensure all components of the facility are maintained in proper working order
- Facility kept in safe and sanitary condition
- Fail to maintain all surfaces of the deck and walls in a sanitary condition
- The premise appears to be free from conditions that might be a health hazard
- Fail to maintain facility in sanitary condition
- Total alkalinity is within range of 80 mg/L to 120 mg/L