Skip to content
Loading map…

Queen Nail & Spa

B-2462 Queen St E Brampton ON L6S 5X9 · Manicure / Pedicure

2 inspections

  1. Required

    1 infraction

    • Did operator meet requirements for equipment that is used in invasive services?
      • Ensure all sharps used for invasive procedures are sterile and for single use.
      • Do not use equipment or sharps from packages that are damaged, wet, torn, punctured, unsealed, previously opened, visibly soiled, have been dropped on the floor or compromised in any way.
      • Provide manufacturer documentation that equipment purchased is sterile and states the method used for sterilization (e.g., E.O. gas, gamma ray).
      • The needle cartridge system must have proof from the manufacturer that it has a backflow preventer/protective membrane.
      • Ensure equipment is not used beyond the expiry date provided by the manufacturer. Expired items must be discarded appropriately.
  2. Required

    1 infraction

    • Did operator properly disinfect equipment and surfaces?
      • Disinfect reusable equipment after use on a client to prevent disease transmission.
      • Disinfect reusable equipment with appropriate disinfectant required for the equipment.
      • Fully immerse reusable equipment in the disinfectant.
      • Clean and low-level disinfect low-risk environmental surfaces (e.g., manicure/waxing tables, chairs, or beds that are covered with a single-use towel/ cover) at the end of the day or when visibly soiled.
      • Clean and low-level disinfect high-risk environmental surfaces (e.g., tattoo tables, beds, or chairs where invasive procedures are carried out) after every use.
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Intermediate-level disinfect equipment such as nail clippers, cuticle nippers, nail drill bits, ear piercing device, single-use ink caps, tweezers and scissors used in hair removal services.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.
      • High-level disinfect equipment that holds, manipulates or contacts sterile items (e.g., needle probe holder, microblading handle, microneedle roller handle, micropigmentation reusable needle sleeve and front casing).