Skip to content
Loading map…

Tippy Toes Nail & Spa

D2-25 Gateway Blvd Brampton ON L6T 4X2 · Manicure / Pedicure

Inspection summary

Tippy Toes Nail & Spa has been inspected 3 times by Peel Public Health (Region of Peel) since December 2, 2024. The most recent inspection, on August 5, 2026, recorded 2 infractions.

None of the 3 inspections on record were free of infractions. In the past 12 months there was 1 inspection with 2 infractions recorded. The higher-risk findings here relate to: Food source, labelling and allergens and Protecting food from contamination.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Food source, labelling and allergensHigher risk

    Products used on clients must come from approved sources, stay in their original labelled containers and be thrown out when they are expired or contaminated. Unlabelled products make it impossible to know what a client is being exposed to.

    Recorded 2 times across 2 separate inspections, most recently on August 5, 2026. For example: Did operator discard single use equipment immediately after each use?

  • Protecting food from contaminationHigher risk

    Clean and used instruments, towels and supplies must be kept apart, and products such as wax, creams and inks must be dispensed so they cannot be contaminated between clients (no double-dipping). Mixing clean and dirty items is a direct route for infection.

    Recorded once on August 1, 2025. For example: Did operator store and dispense products in a manner to prevent contamination?

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 3 times across 3 separate inspections, most recently on August 5, 2026. For example: Did operator properly disinfect equipment and surfaces?

About this data

These results come from Peel Public Health (Region of Peel), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

3 inspections

  1. Required

    2 infractions

    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
      • Roll-on wax cartridge must be used for one client only and discarded immediately after use. Do not reuse and/or refill roll-on wax cartridges.
    • Did operator properly disinfect equipment and surfaces?
      • Disinfect reusable equipment after use on a client to prevent disease transmission.
      • Disinfect reusable equipment with appropriate disinfectant required for the equipment.
      • Intermediate-level disinfect equipment such as nail clippers, cuticle nippers, nail drill bits, ear piercing device, single-use ink caps, tweezers and scissors used in hair removal services.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
      • Provide a high-level disinfectant and ensure it is easily accessible.
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.
  2. Required

    3 infractions

    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
      • Roll-on wax cartridge must be used for one client only and discarded immediately after use. Do not reuse and/or refill roll-on wax cartridges.
    • Did operator store and dispense products in a manner to prevent contamination?
      • Dispense products (e.g., creams, oils, ointments, gels, wax and skin antiseptics) in a manner to prevent contamination.
      • Store products in a manner to prevent contamination.
      • Ensure products are not topped up with fresh product (e.g., do not add new solution to the current solution). If a reusable container is used, it must be emptied, cleaned, disinfected, rinsed, and dried before refilling.
      • Manicure/pedicure: Dispense products (e.g., paraffin wax, nail gels/powders) in a manner to prevent contamination.
    • Did operator properly disinfect equipment and surfaces?
      • Fully immerse reusable equipment in the disinfectant.
      • Provide an intermediate-level disinfectant and ensure it is easily accessible.
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
      • Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
      • Pedicure basin filter/screen (e.g., magnet screens): Remove, dismantle, clean then intermediate level disinfect after every use.
      • Provide a high-level disinfectant and ensure it is easily accessible.
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.
  3. Required

    1 infraction

    • Did operator properly disinfect equipment and surfaces?
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.

Nearby inspected facilities