Skip to content
Loading map…

Sierras of Country Hills - Hot Tub

728 Country Hills Road NW Calgary AB T3K 5K8 · Aquatic Facility

Inspection summary

Sierras of Country Hills - Hot Tub has been inspected 5 times by Alberta Health Services (Environmental Public Health) since November 21, 2023. The most recent inspection, on April 9, 2026, recorded 2 infractions.

None of the 5 inspections on record were free of infractions. In the past 12 months there was 1 inspection with 2 infractions recorded. The higher-risk findings here relate to: Chemicals and toxic substances and Pool and spa water quality.

Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 5 times across 5 separate inspections, most recently on April 9, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 5 times across 3 separate inspections, most recently on December 27, 2023. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded once on April 9, 2026. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

5 inspections

  1. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Repeat violation cited on April 9, 2026:The Total alkalinity was measured at 198 mg/l. Adjust TA to measure between 60 to 180 mg/l.There has been consistent violation with the TA levels.Daily record the total alkalinity level in the hot tub to determine the fluctuations. Violation cited on August 14, 2025:Total Alkalinity measured 59 ppm.Maintain Total Alkalinity between 60 to 180 ppm.Previous violation:Alkalinity measured 29 ppm. Please raise alkalinity to at least 60 ppm.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Daily testing and readings for total chlorine and combined chlorine were not completed.Test and record the readings for TC and CC.Operating records must be maintained to provide information regarding time of and observations and readings for pH, and the free, total and combined chlorine residual.
  2. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Violation cited on August 14, 2025:Total Alkalinity measured 59 ppm.Maintain Total Alkalinity between 60 to 180 ppm.Previous violation:Alkalinity measured 29 ppm. Please raise alkalinity to at least 60 ppm.
  3. Risk Management Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 760 CFU/Ml for Dec 22 2023 sample. Treat and resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity measured 29 ppm. Please raise alkalinity to at least 60 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The manual readings measured pH to be 6.99 while the system readings showed 7.4. Calibration or replacement of probe may be required.
  4. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity measured 29 ppm. Please raise alkalinity to at least 60 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The manual readings measured pH to be 6.99 while the system readings showed 7.4. Calibration or replacement of probe may be required.
  5. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity measured 29 ppm. Please raise alkalinity to at least 60 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The manual readings measured pH to be 6.99 while the system readings showed 7.4. Calibration or replacement of probe may be required.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The main drain cover is cracked and expired. Drain the hot tub and replace ASAP.