Sierras of Country Hills - Pool
728 Country Hills Road NW Calgary AB T3K 5K8 · Aquatic Facility
3 inspections
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Repeat violation cited on April 9, 2026:The manual reading indicated pH to be 7.31, while the DSR automated controller read 8.03. The automated controller reading exceeded the manual reading.Fix or replace the DSR automated controller. Automated controller readings must be consistent with any manual tests. Violation cited on August 14, 2025:Manual reading indicated pH to be 7.41, while the automated controller read 8.26.Replace the probe or controller to read values within +or- 0.2 - 0.3Previous violation:Manual readings indicated pH to be 7.37, while controller read 8.34. Please recalibrate system, change probes or change controller to ensure the values match within 0.2-0.3.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Daily testing and readings for total chlorine and combined chlorine were not completed.Test and record the readings for TC and CC.Operating records must be maintained to provide information regarding time of and observations and readings for pH, and the free, total and combined chlorine residual.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Violation cited on August 14, 2025:Manual reading indicated pH to be 7.41, while the automated controller read 8.26.Replace the probe or controller to read values within +or- 0.2 - 0.3Previous violation:Manual readings indicated pH to be 7.37, while controller read 8.34. Please recalibrate system, change probes or change controller to ensure the values match within 0.2-0.3.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Manual readings indicated pH to be 7.37, while controller read 8.34. Please recalibrate system, change probes or change controller to ensure the values match within 0.2-0.3.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?