STATION PARK UNION TOWERS - SPA (SMALLER)

#5 Wellington St S, Kitchener ON N2G 0E3 · Facility

10 inspections

  1. Compliance Inspection

    3 infractions

    • All components of the filtration, recirculation, and chemical feed systems are in continuous operation and maintained in proper working order
      • Ensure all components of the filtration, recirculation system and chemical feeders are maintained in good working condition
    • Manual chemical testing in compliance
      • Automatic Sensing Device - Ensure pH, alkalinity, Free Available Chlorine, total chlorine or bromine residuals and water clarity are tested manually one half hour before bathers are admitted, and checked at least every 4 hours during the operating day
    • Other records signed and completed
      • Ensure emergency stop button is tested and recorded at least once every 30 operating days
      • Ensure water outlet cover inspections are recorded at least once every 30 operating days along with time of day the test was completed and by whom
      • Ensure vacuum release mechanism is tested and recorded at least once every 30 days
  2. Compliance Inspection

    0 infractions

  3. Compliance Inspection

    0 infractions

  4. Re-inspection

    0 infractions

  5. Compliance Inspection

    2 infractions

    • Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
      • CLOSE SPA
    • Pool operator designated and trained in public pool operation, maintenance, filtration systems, water chemistry and all relevant safety and emergency procedures
      • Ensure an operator is designated and trained
  6. Compliance Inspection

    0 infractions

  7. Re-inspection

    0 infractions

  8. Compliance Inspection

    6 infractions

    • Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
      • CLOSE SPA
    • Sanitizer levels in compliance
      • Maintain Free Available Chorine between 5mg/L (5ppm) - 10mg/L (10ppm)
    • pH is within range of 7.2 to 7.8
      • Maintain pH between 7.2 to 7.8
    • Suction system equipped with a vacuum relief mechanism
      • Ensure suction system is equipped with vacuum relief mechanism that includes a vacuum release system, a vacuum limit system or an approved equivalent
    • Total alkalinity is between 60 mg/L (60 ppm) and 180 mg/L (180 ppm)
      • Maintain total alkalinity between 60mg/L (60ppm) and 180 mg/L (180 ppm)
    • Requirements for steps used for entering and exiting spa are met (if provided)
      • Ensure steps are equipped with a handrail
  9. Compliance Inspection

    2 infractions

    • Sanitizer levels in compliance
      • Maintain Free Available Chorine between 5mg/L (5ppm) - 10mg/L (10ppm)
    • pH is within range of 7.2 to 7.8
      • Maintain pH between 7.2 to 7.8
  10. Compliance Inspection

    2 infractions

    • Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
      • CLOSE SPA
    • Requirements for steps used for entering and exiting spa are met (if provided)
      • Ensure bands of contrasting colour are applied along edges of each step
      • Ensure steps have a non-slip surface or treads