STATION PARK UNION TOWERS - SPA (SMALLER)
#5 Wellington St S, Kitchener ON N2G 0E3 · Facility
10 inspections
- Compliance Inspection
3 infractions
- All components of the filtration, recirculation, and chemical feed systems are in continuous operation and maintained in proper working order
- Ensure all components of the filtration, recirculation system and chemical feeders are maintained in good working condition
- Manual chemical testing in compliance
- Automatic Sensing Device - Ensure pH, alkalinity, Free Available Chlorine, total chlorine or bromine residuals and water clarity are tested manually one half hour before bathers are admitted, and checked at least every 4 hours during the operating day
- Other records signed and completed
- Ensure emergency stop button is tested and recorded at least once every 30 operating days
- Ensure water outlet cover inspections are recorded at least once every 30 operating days along with time of day the test was completed and by whom
- Ensure vacuum release mechanism is tested and recorded at least once every 30 days
- All components of the filtration, recirculation, and chemical feed systems are in continuous operation and maintained in proper working order
- Compliance Inspection
0 infractions
- Compliance Inspection
0 infractions
- Re-inspection
0 infractions
- Compliance Inspection
2 infractions
- Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
- CLOSE SPA
- Pool operator designated and trained in public pool operation, maintenance, filtration systems, water chemistry and all relevant safety and emergency procedures
- Ensure an operator is designated and trained
- Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
- Compliance Inspection
0 infractions
- Re-inspection
0 infractions
- Compliance Inspection
6 infractions
- Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
- CLOSE SPA
- Sanitizer levels in compliance
- Maintain Free Available Chorine between 5mg/L (5ppm) - 10mg/L (10ppm)
- pH is within range of 7.2 to 7.8
- Maintain pH between 7.2 to 7.8
- Suction system equipped with a vacuum relief mechanism
- Ensure suction system is equipped with vacuum relief mechanism that includes a vacuum release system, a vacuum limit system or an approved equivalent
- Total alkalinity is between 60 mg/L (60 ppm) and 180 mg/L (180 ppm)
- Maintain total alkalinity between 60mg/L (60ppm) and 180 mg/L (180 ppm)
- Requirements for steps used for entering and exiting spa are met (if provided)
- Ensure steps are equipped with a handrail
- Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
- Compliance Inspection
2 infractions
- Sanitizer levels in compliance
- Maintain Free Available Chorine between 5mg/L (5ppm) - 10mg/L (10ppm)
- pH is within range of 7.2 to 7.8
- Maintain pH between 7.2 to 7.8
- Sanitizer levels in compliance
- Compliance Inspection
2 infractions
- Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
- CLOSE SPA
- Requirements for steps used for entering and exiting spa are met (if provided)
- Ensure bands of contrasting colour are applied along edges of each step
- Ensure steps have a non-slip surface or treads
- Premises is operated and maintained free from every condition that may be a potential/immediate health hazard