Skip to content
Loading map…

The Queen By Bushra

14-2580 Shepard Ave Mississauga ON L5A 3Z5 · Aesthetics

6 inspections

  1. Follow-up

    0 infractions

  2. Follow-up

    2 infractions

    • Did operator meet requirements for equipment that is used in invasive services?
      • Do not use equipment or sharps from packages that are damaged, wet, torn, punctured, unsealed, previously opened, visibly soiled, have been dropped on the floor or compromised in any way.
    • Did operator maintain client records for invasive services?
      • Keep records for invasive procedures including, which procedure was done and the part of the body the procedure was done to, client name and contact information, service provider name and contact information, explanation of and risks associated with the procedure, date of procedure and lot numbers and expiry date of the pre-packaged sterile equipment used in the procedure. (Show More)
      • In the client record, document lot number and expiry date of the pre-packaged sterile equipment used in the procedure.
      • Before starting the procedure, provide clients with an explanation of and risks associated with the invasive procedure.
      • In the client record, make note of when you explain the service and any risks associated with the service to the client.
      • Keep invasive procedure records for one year at personal service setting and readily available for an additional two years.
      • Provide records to a medical officer of health or public health inspector on request.
      • Records must be made by the operator or personal service worker who provided the explanation and information of the invasive procedure.
      • Provide clients with verbal and written after-care instructions for invasive and laser services.
  3. Required

    8 infractions

    • Did operator notify Peel Public Health of the intention to operate, add additional services and renovate or reconstruct the personal service setting?
      • Provide written notice to Peel Public Health of the intention to add additional personal services at least 14 days before starting to provide the additional services.
    • Does the hand washing sink meet all requirements?
      • Provide hand washing sink within the premises of the personal service setting that is conveniently located to the work area.
      • Provide hand washing sink within the premises of the personal service setting that is accessible at all times.
      • Provide a method of hand drying that uses single-service products or a hot air dryer in close proximity to the hand washing sink.
    • Does the equipment cleaning sink meet all requirements?
      • Ensure the equipment cleaning sink is continuously supplied with potable hot and cold running water under pressure. Portable/mobile sinks are not permitted.
      • Ensure the sink is capable of immersing the largest piece of reusable equipment.
      • Ensure there is adequate counter space to prepare the reusable equipment for use and re-use.
      • Ensure the sink is sufficiently separated from where personal services are provided to prevent contamination.
    • Did operator maintain setting and work surfaces in a safe and sanitary condition?
    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
      • Roll-on wax cartridge must be used for one client only and discarded immediately after use. Do not reuse and/or refill roll-on wax cartridges.
    • Did operator provide a sharps container and properly dispose sharps?
      • Immediately after use, dispose all sharps (e.g., razor blades, credo blades, needles, lancets) in a sharps container that is located in close proximity to where the personal service is provided.
      • Dispose all sharps used for hairdressing in a sharps container that is located in close proximity to where the personal service is provided.
      • Provide a puncture and leak resistant sharps container with a fill line designed for the safe disposal of sharps compliant with the Canadian Standards Association.
    • Did operator properly disinfect equipment and surfaces?
      • Fully immerse reusable equipment in the disinfectant.
    • Did operator keep disinfection records?
      • Keep disinfection records that include: name of the disinfectant, concentration of disinfectant, date prepared, and date discarded.
      • Keep disinfection records for one year at personal service setting and keep readily available for an additional two years.
      • Provide the records to a medical officer of health or public health inspector on request.
  4. Required

    2 infractions

    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
      • Roll-on wax cartridge must be used for one client only and discarded immediately after use. Do not reuse and/or refill roll-on wax cartridges.
    • Did operator properly disinfect equipment and surfaces?
  5. Follow-up

    0 infractions

  6. Required

    3 infractions

    • Did operator notify Peel Public Health of the intention to operate, add additional services and renovate or reconstruct the personal service setting?
      • Provide written notice to Peel Public Health of reconstruction or renovation of the personal service setting at least 14 days before starting renovation/construction at which time no personal services are offered.
    • Did operator provide a sink for cleaning reusable equipment?
      • Provide at least one sink designated for cleaning reusable equipment.
      • Ensure the equipment cleaning sink is continuously supplied with potable hot and cold running water under pressure. Portable/mobile sinks are not permitted.
      • The hand washing sink cannot be used for cleaning reusable equipment.
    • Did operator properly disinfect equipment and surfaces?
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.