RED LINE TAP
7006-7008 N GLENWOOD AVE, CHICAGO, IL 60626 · Restaurant
8 inspections
- Canvass
0 infraction
- Canvass
4 infractions
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- NOTED TILES MISSING FROM FLOOR IN BACK OF TOILET IN MENS RESTROOM.INSTRUCTED MANAGEMENT TO REPLACE TILES AND TO CLEAN FLOOR ON SIDE OF WALK-IN COOLER.
- 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
- NOTED NO VENTILLATION IN RESTROOMS. INSTRUCTED MANAGEMENT TO INSTALL VENTILLATION IN RESTROOMS. NOTED NO DRAIN PIPE FROM CONDENSER UNIT IN BEER WALK-IN COOLER.INSTRUCTED MANAGEMENT TO CONNECT A LINE FROM THE CONDENSER TO THE DRAIN.
- 40. REFRIGERATION AND METAL STEM THERMOMETERS PROVIDED AND CONSPICUOUS
- NOTED NO THERMOMETERS BI-METAL OR REFIGERATION THERMOMETERS IN COOLERS.INSTRUCTED MANAGEMENT TO GET THERMOMETERS.
- 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
- NOTED CLUTTER(I.E.UNUSED STORE FIXTURES) AT REAR COURTYARD AREA.INSTRUCTED MANAGEMENT TO REMOVE OR REORGANIZE FOR BETTER PEST CONTROL MONITORING.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- Canvass
0 infraction
- Canvass
4 infractions
- 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
- DEFROST WALK IN FREEZER ADJACENT TO BAR. EXCESSIVE ICE ACCUMULATION ON THE CONDENSER. INSTRUCTED TO DEFROST, CLEAN, AND MAINTAIN.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- OBSERVED FLOORS NOT CLEAN (CORNERS)IN THE FOLLOWING AREAS; BEHIND BAR AND IN BEVERAGE STORAGE ROOM ADJACENT TO BAR. INSTRUCTED TO DETAIL CLEAN AND MAINTAIN.
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- CEILING VENT MISSING IN TOILET ROOM. INSTRUCTED TO REPAIR AND MAINTAIN.
- 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
- OBSERVED LIGHTS MISSING IN TOILET ROOM. INSTRUCTED TO INSTALL WORKING LIGHTS AND MAINTAIN.
- 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
- Canvass
0 infraction
- Canvass
2 infractions
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- FOUND FLOORS NOT CLEAN UNDER BAR AREAS.
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- FOUND INTERIOR WALLS, FLOORS, AND CEILING OF WALK IN COOLER NOT CLEAN.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- License Re-Inspection
1 infraction
- 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
- NO MOP SINK ON PREMISES ALSO OBSERVED LOW HOT WATER PRESSURE AT WOMENS WASHROOM HANDWASH BOWL. INSTRUCTED MANAGER TO PROVIDE MOP SINK ON PREMISES WITH RUNNING HOT AND COLD WATER AND BACK FLOW PREVENTION DEVICE ALSO MUST INCREASE HOT WATER PRESSURE AT WOMENS WASH ROOM SINK.
- 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
- License
3 infractions
- 11. ADEQUATE NUMBER, CONVENIENT, ACCESSIBLE, DESIGNED, AND MAINTAINED
- NO EXPOSED HANDWASH BOWL AT BAR AREA. INSTRUCTED MANAGER TO PROVIDE EXPOSED HANDWASH BOWL AT BAR WITH RUNNING HOT AND COLD WATER. CRITICAL VIOLATION 7-38-030.
- 18. NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS
- FRONT DOOR NOT RODENT PROOFED, OBSERVED 1/2 INCH GAP AT BOTTOM OF SAID DOOR ALSO NO PEST CONTROL LOG BOOK FOR LOCATION. INSTRUCTED MANAGER MUST RODENT PROOF DOOR AND PROVIDE PEST CONTROL LOG BOOK FROM A LICENSED ILLINOIS PEST CONTROL OPERATOR. SEROIUS VIOLATION 7-38-020.
- 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
- NO MOP SINK ON PREMISES ALSO OBSERVED LOW HOT WATER PRESSURE AT WOMENS WASHROOM HANDWASH BOWL. INSTRUCTED MANAGER TO PROVIDE MOP SINK ON PREMISES WITH RUNNING HOT AND COLD WATER AND BACK FLOW PREVENTION DEVICE ALSO MUST INCREASE HOT WATER PRESSURE AT WOMENS WASH ROOM SINK.
- 11. ADEQUATE NUMBER, CONVENIENT, ACCESSIBLE, DESIGNED, AND MAINTAINED