Skip to content
Loading map…

10045 117 Street NW - Swimming Pool

10045 117 Street NW Edmonton AB T5K 1W8 · Aquatic Facility

Inspection summary

10045 117 Street NW - Swimming Pool has been inspected 9 times by Alberta Health Services (Environmental Public Health) since November 20, 2023. The most recent inspection, on August 20, 2026, recorded 1 infraction.

1 of 9 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Food temperature control.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 9 times across 7 separate inspections, most recently on August 20, 2026. For example: Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 2 times across 2 separate inspections, most recently on August 17, 2026. For example: Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 3 times across 3 separate inspections, most recently on March 7, 2025. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 2 times across 2 separate inspections, most recently on June 17, 2025. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

9 inspections

  1. Risk Management Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Potential pest evidence was observed in the cabinet under the hand sink in the women's washroom. Please install sticky traps to confirm if there's evidence of pests, or consult your pest control specialist.
  2. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on 14 Aug 2026 was unsatisfactory: HPC 1270 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Potential pest evidence was observed in the cabinet under the hand sink in the women's washroom. Please install sticky traps to confirm if there's evidence of pests, or consult your pest control specialist.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. All metals grates on the drains surrounding the pool deck are loose and easily removeable. Please ensure all elements of the deck are maintained in a condition where they cannot potentially cause harm.2. The ceiling vent above the second emergency exit is not properly installed. Please ensure the ceiling fan is properly repositioned. 3. The finishings to the bottom of the women's bathroom sink is peeling off. Please ensure all surfaces are smooth, durable, easily cleanable and non-porous. 4. The temperatures for the men and women's bathroom hand sink have the potential for scalding at 58.4C and 57.3C. Please ensure the water temperature is adjusted to no more than 45C. 5. There are cracks observed in the grouting around the deck area. Please monitor these and repair if they continue to deteriorate.
  3. Demand Inspection

    3 infractions

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Potential pest evidence was observed in the cabinet under the hand sink in the women's washroom. Please install sticky traps to confirm if there's evidence of pests, or consult your pest control specialist.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • 1. All metals grates on the drains surrounding the pool deck are loose and easily removeable. Please ensure all elements of the deck are maintained in a condition where they cannot potentially cause harm.2. The ceiling vent above the second emergency exit is not properly installed. Please ensure the ceiling fan is properly repositioned. 3. The finishings to the bottom of the women's bathroom sink is peeling off. Please ensure all surfaces are smooth, durable, easily cleanable and non-porous. 4. The temperatures for the men and women's bathroom hand sink have the potential for scalding at 58.4C and 57.3C. Please ensure the water temperature is adjusted to no more than 45C. 5. There are cracks observed in the grouting around the deck area. Please monitor these and repair if they continue to deteriorate.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Expired water quality testing chemicals were observed, Total Alkalinity reagent and Calcium Hardness reagent expired. Operator disposed of expired chemicals and replaced with nonexpired Total Alkalinity Reagent. Please ensure that all elements of the water quality testing kit are maintained in good working order.
  4. Risk Management Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An updated anti-entrapment compliance plan is required as a new suction outlet was installed in the pool. Forward a completed plan for review to the undersigned.
  5. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample 25EN-057E00885 submitted on February 26, 2025, was unsatisfactory: HPC 460.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • New suction outlet fitting was installed November 24, 2024. Pool service provider confirmed installation. An Aquastar 32PD101 Propeller Drain was installed. Please note that since this suction outlet is unblockable the SVRS device previously installed is no longer required.Confirmation of maximum flow for the existing pump is required. Installed must confirm installation is compliance
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An updated anti-entrapment compliance plan is required as a new suction outlet was installed in the pool. Forward a completed plan for review to the undersigned.
  6. Risk Management Inspection

    2 infractions

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • New suction outlet fitting was installed November 24, 2024. Pool service provider confirmed installation. An Aquastar 32PD101 Propeller Drain was installed. Please note that since this suction outlet is unblockable the SVRS device previously installed is no longer required.Confirmation of maximum flow for the existing pump is required. Installed must confirm installation is compliance
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An updated anti-entrapment compliance plan is required as a new suction outlet was installed in the pool. Forward a completed plan for review to the undersigned.
  7. Monitoring Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on 17 Nov 2023 was unsatisfactory: HPC 1140 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  9. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on 17 Nov 2023 was unsatisfactory: HPC 2630 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Testing of the SVRS secondary anti-entrapment device was not being documented monthly. Ensure the test results for the device are documented once per month as per manufactures specifications.

Nearby inspected facilities