Skip to content
Loading map…

10711 47 Avenue NW - Swimming Pool

10711 47 Avenue NW Edmonton AB T6H 5J1 · Aquatic Facility

Inspection summary

10711 47 Avenue NW - Swimming Pool has been inspected 9 times by Alberta Health Services (Environmental Public Health) since November 7, 2023. The most recent inspection, on July 23, 2026, found no infractions.

5 of 9 inspections on record found no infractions at all. In the past 12 months there were 5 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 4 times across 4 separate inspections, most recently on June 29, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded once on June 5, 2026. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

9 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the microbiological water sample 26EN-177E00193 submitted on June 26, 2026, was unsatisfactory: Total coliforms were present.
  3. Monitoring Inspection

    2 infractions

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • The main drain covers were replaced. No notification to EPH-AHS has been made, and no updated Anti-Entrapment Compliance Plan was submitted for review. The violation was addressed during the inspection. New drain covers according to the plan were Aquastar 32PD101, installed on April 22, 2025, which will expire on April 22, 2030.
    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • 1. The main drain covers were replaced. No notification to EPH-AHS has been made, and no updated Anti-Entrapment Compliance Plan was submitted for review. The violation was addressed during the inspection. New drain covers according to the plan were Aquastar 32PD101, installed on April 22, 2025, which will expire on April 22, 2030.2. The cartridge filter was replaced with a high-rate sand filter, and no notification about the replacement was submitted to EPH-AHS. The information was submitted during the inspection: The high-rate sand filter, Pentair Tagelus TA100, SA 4.9ft2.
  4. Risk Management Inspection

    0 infractions

  5. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the microbiological water sample 26EN-128E00177 submitted on May 8, 2026, was unsatisfactory: HPC 140.
  6. Risk Management Inspection

    0 infractions

  7. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The turnover period was 6.6 hours based on a volume of 21449 gallons and flow rate about 205 lpm/54 gpm. Note: flow rate was 265 lpm/70 gpm during the previous inspection.
  8. Monitoring Inspection

    0 infractions

  9. Risk Management Inspection

    0 infractions

Nearby inspected facilities