Skip to content
Loading map…

11808 100 Avenue NW - Swimming Pool

11808 100 Avenue NW Edmonton AB T5K 0K4 · Aquatic Facility

Inspection summary

11808 100 Avenue NW - Swimming Pool has been inspected 3 times by Alberta Health Services (Environmental Public Health) since September 4, 2024. The most recent inspection, on June 22, 2026, found no infractions.

1 of 3 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 3 times across 2 separate inspections, most recently on June 18, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

3 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The pool water temperature was measured at 31.8C. The thermostat was set to 89F. If the pool is maintained at >30C then the water samples submitted for microbiological testing must be selected as >30C so that a Psuedomonas test is completed. Operator adjusted the thermostat to 86F.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow rate of the system exceeds the filtration rate of the sand filter. The current flow of the pool is 90 GPM. The filter cannot exceed 74 GPM. Make the necessary adjustments to the variable speed pump to maintain the flow at or below 74 GPM.
  3. Monitoring Inspection

    1 infraction

    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • Ensure the automatic pump shut off is tested every 2 weeks. Testing was done 1/month.

Nearby inspected facilities

Own this business? Add a badge to your website