Skip to content
Loading map…

Acme Pool - Swimming Pool

219 Allison Street Acme AB T0M 0A0 · Aquatic Facility

Inspection summary

Acme Pool - Swimming Pool has been inspected 16 times by Alberta Health Services (Environmental Public Health) since May 15, 2024. The most recent inspection, on June 10, 2026, found no infractions.

6 of 16 inspections on record found no infractions at all. In the past 12 months there were 5 inspections with 15 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 20 times across 10 separate inspections, most recently on June 9, 2026. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 4 times across 4 separate inspections, most recently on June 9, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

16 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH= 6.7
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • No skimming action was observed during the inspection.The pool water level was elevated due to excessive rainfall, resulting in overflow conditions. The high-water level may have reduced the effectiveness of the skimmers by limiting the maximum flow of water through them, thereby restricting proper surface skimming action.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Water was not sufficiently clear to inspect the main drains at the bottom of the pool.
  3. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total Coliforms present.The pool water level was elevated due to excessive rainfall, resulting in overflow conditions. The high water level reduced the effectiveness of the skimmers by limiting the maximum flow of water through them, thereby restricting proper surface skimming action. Reduced skimming efficiency may have adversely affected water circulation and the removal of surface contaminants, potentially contributing to the unsatisfactory bacteriological result.The operator is advised to lower the water level to restore proper skimmer function, ensure adequate circulation and filtration, maintain required disinfectant residuals, and submit follow-up bacteriological samples to verify water quality.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC >57,000 CFU/ml
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH= 6.7
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • No skimming action was observed during the inspection.The pool water level was elevated due to excessive rainfall, resulting in overflow conditions. The high-water level may have reduced the effectiveness of the skimmers by limiting the maximum flow of water through them, thereby restricting proper surface skimming action.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Water was not sufficiently clear to inspect the main drains at the bottom of the pool.
  4. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total Coliforms present.The pool water level was elevated due to excessive rainfall, resulting in overflow conditions. The high water level reduced the effectiveness of the skimmers by limiting the maximum flow of water through them, thereby restricting proper surface skimming action. Reduced skimming efficiency may have adversely affected water circulation and the removal of surface contaminants, potentially contributing to the unsatisfactory bacteriological result.The operator is advised to lower the water level to restore proper skimmer function, ensure adequate circulation and filtration, maintain required disinfectant residuals, and submit follow-up bacteriological samples to verify water quality.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH= 6.7
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • No skimming action was observed during the inspection.The pool water level was elevated due to excessive rainfall, resulting in overflow conditions. The high-water level may have reduced the effectiveness of the skimmers by limiting the maximum flow of water through them, thereby restricting proper surface skimming action.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Water was not sufficiently clear to inspect the main drains at the bottom of the pool.
  5. Monitoring Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH= 6.7
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • No skimming action was observed during the inspection.The pool water level was elevated due to excessive rainfall, resulting in overflow conditions. The high-water level may have reduced the effectiveness of the skimmers by limiting the maximum flow of water through them, thereby restricting proper surface skimming action.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Water was not sufficiently clear to inspect the main drains at the bottom of the pool.
  6. Demand Inspection

    0 infractions

  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC @ 3950.
  9. Risk Management Inspection

    0 infractions

  10. Monitoring Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • No Water Sample has been submitted yet this year.Ensure that a sample is taken next week in order to confirm water quality/safety.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • A couple of the Pool Skimmers were partially blocked with leaves at the time of Inspection.Ensure that the Skimmers are being cleaned out more regularly in order to maintain adequate flow. This was Corrected during the Inspection.
  11. Risk Management Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC @ 1480.
  13. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC @ 890.
  14. Risk Management Inspection

    0 infractions

  15. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • No Water Sample has been submitted yet this year.Ensure that a sample is taken next week in order to confirm water quality/safety.
  16. Monitoring Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • No Water Sample has been submitted yet this year.Ensure that a sample is taken next week in order to confirm water quality/safety.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • A couple of the Pool Skimmers were partially blocked with leaves at the time of Inspection.Ensure that the Skimmers are being cleaned out more regularly in order to maintain adequate flow. This was Corrected during the Inspection.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Proof of Pool Operator training Certificate was not observed at the time of Inspection.Ensure that Pool Operator training Certificates are kept on site at all times in order to prove that adequate training has been taken.

Nearby inspected facilities