Best Western Premier - Whirlpool

5207 50 Avenue Leduc AB T9E 6V3 · Aquatic Facility

Inspection summary

Best Western Premier - Whirlpool has been inspected 7 times by Alberta Health Services (Environmental Public Health) since June 5, 2024. The most recent inspection, on June 2, 2026, recorded 1 infraction.

2 of 7 inspections on record found no infractions at all. In the past 12 months there were 3 inspections with 6 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 6 times across 4 separate inspections, most recently on June 2, 2026. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 2 times across 2 separate inspections, most recently on June 2, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

7 inspections

  1. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The Filtration Rate was 17.62gpm/sq.ft (55gpm/3.12 sq.ft).Please ensure that the rate of filtration for a high-rate sand filter is no more than 8.5 litres per second per square meter (12.5 gallons per minute per square foot) for whirlpools.If the pool is constructed before November 30, 2006 the rate of filtration for a high rate sand filter must comply with manufactures specifications and maintain water quality in accordance with Section 4.0, 6.0 and 8.0 of the Pool Standards. AR 204/2014 s 12; Pool Standards, July 2014 (Amended January 2018) s 3.3.2.
  2. Demand Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • During the inspection, the free available chlorine was measured at 0.58, and the total chlorine was measured at 1.60, indicating that disinfectant levels were below the required operating range. The pool operator immediately corrected the issue by adjusting the automated disinfection system to increase chlorine output and by manually adding chlorine. Following these corrective actions, the water was retested. The test unit displayed an “OR” (Out of Range) message, indicating that chlorine levels had risen above the measurable limit of the device. The operator will continue to monitor chlorine levels to ensure they return to and remain within the acceptable operating range.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The Filtration Rate was 17.62gpm/sq.ft (55gpm/3.12 sq.ft).Please ensure that the rate of filtration for a high-rate sand filter is no more than 8.5 litres per second per square meter (12.5 gallons per minute per square foot) for whirlpools.If the pool is constructed before November 30, 2006 the rate of filtration for a high rate sand filter must comply with manufactures specifications and maintain water quality in accordance with Section 4.0, 6.0 and 8.0 of the Pool Standards. AR 204/2014 s 12; Pool Standards, July 2014 (Amended January 2018) s 3.3.2.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Grime buildup was observed inside the skimmer during the inspection. Please ensure that all skimmers are cleaned and maintained regularly.
  3. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on May 13 results: Pseudomonas aeruginosa present
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on May 13 sample results: HPC 130
  4. Monitoring Inspection

    0 infractions

  5. Monitoring Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Trent Bernier, operator of the facility is informed that water test results of the water sample submitted on May 26, 2025 indicated that Pseudomonas is isolated. Operator agreed to take care of it.
  6. Risk Management Inspection

    0 infractions

  7. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined Chlorine was measured to be at 1.72ppm.Please ensure combined chlorine is maintained at the lowest possible level.