Calgary Winter Club - Whirlpool
4611 14 Street NW Calgary AB T2K 1J7 · Aquatic Facility
16 inspections
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The turnover rate of the hot tub with a volume greater than 4 m3 (1056 USG) must be 20 minutes. The turnover rate of the hot tub with a volume 3000USG is 24.78 minutes.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on 30/09/2025 was rejected due to non-urgent sample received during the weekend/holiday without approval.Resample
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity was too low, measured at 34 mg/L.Adjust alkalinity and ensure it is maintained between 60mg/L to 180 mg/L.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sampling collected on 06/05/2025 was cancelled due to time of collection not indicated on the requisition form.Resample
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity was too low, measured at 34 mg/L.Adjust alkalinity and ensure it is maintained between 60mg/L to 180 mg/L.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on 15/04 09:01 was cancelled due to no identification number on the bottle.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity was too low, measured at 34 mg/L.Adjust alkalinity and ensure it is maintained between 60mg/L to 180 mg/L.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Description: Water sample collected on Jan 07/25 was not processed because the collection time was not indicated.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity was too low, measured at 34 mg/L.Adjust alkalinity and ensure it is maintained between 60mg/L to 180 mg/L.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity was too low, measured at 34 mg/L.Adjust alkalinity and ensure it is maintained between 60mg/L to 180 mg/L.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample not processed as the time of collection was not indicated and there was no access number provided. Informed Anna to submit a resample tomorrow - Aug 21/24.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- 2 of 4 skimmers in whirpool were not operational at time of inspection. Ensure that skimmers are operational for adequate removal of surface contamination.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- 2 of 4 skimmers in whirpool were not operational at time of inspection. Ensure that skimmers are operational for adequate removal of surface contamination.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sampled collected on Jun 28, 2024 had Pseudomonas and >57000 CFU/mLID: 24ES-180E00089
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sampled collected on Jun 28, 2024 had Pseudomonas and >57000 CFU/mLID: 24ES-180E00089
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- 2 of 4 skimmers in whirpool were not operational at time of inspection. Ensure that skimmers are operational for adequate removal of surface contamination.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- 2 of 4 skimmers in whirpool were not operational at time of inspection. Ensure that skimmers are operational for adequate removal of surface contamination.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- WC-24-0021094 HPC 250CFU/mLTreat and submit a resample
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- 2 of 4 skimmers in whirpool were not operational at time of inspection. Ensure that skimmers are operational for adequate removal of surface contamination.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- WC-24-0013943Sample not processed no time of collection Submit a resample
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- 2 of 4 skimmers in whirpool were not operational at time of inspection. Ensure that skimmers are operational for adequate removal of surface contamination.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- WC-24-0007957Sample not processed - No time of collection recorded on bottle. Submit a resample with time of collection recorded.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- 2 of 4 skimmers in whirpool were not operational at time of inspection. Ensure that skimmers are operational for adequate removal of surface contamination.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- 2 of 4 skimmers in whirpool were not operational at time of inspection. Ensure that skimmers are operational for adequate removal of surface contamination.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- October 31 sample had Pseudomonas aeruginosa isolated. Please treat and resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?