Skip to content
Loading map…

Canalta Wainwright - Swimming Pool

1510 27 Street SE Wainwright AB T9W 0A4 · Aquatic Facility

14 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on December 30, 3035:TC AbsentHPC 1640 CFU/mLOperator was informed to:- Clean the scum line as needed- Ensure bathers take a shower before using the water- Ensure maximum bather load is being followed- Ensure water chemistry is within range- Ensure circulation and filtration systems are working properly- Ensure proper turnover- Resample next week
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Operator to confirm that the maintenance lead - Roman, is enrolled in a certified pool operator course.
  3. Risk Management Inspection

    1 infraction

    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Operator to confirm that the maintenance lead - Roman, is enrolled in a certified pool operator course.
  4. Risk Management Inspection

    1 infraction

    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Operator to confirm that the maintenance lead - Roman, is enrolled in a certified pool operator course.
  5. Monitoring Inspection

    0 infractions

  6. Monitoring Inspection

    0 infractions

  7. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • - Main pool had elevated/high levels of HPC in water sample. Discussed with pool operator at this time, requested he check main pool disinfection system and pool chemistry balance again. - This water body has had three consecutive unsatisfactory water samples.
  8. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • - Main pool had elevated/high levels of HPC in water sample. Discussed with pool operator at this time, requested he check main pool disinfection system and pool chemistry balance again. - This water body has had three consecutive unsatisfactory water samples.
  9. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • - Main pool had elevated/high levels of HPC in water sample. Discussed with pool operator at this time, requested he check main pool disinfection system and pool chemistry balance again. - This water body has had three consecutive unsatisfactory water samples.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • - Alkalinity = 36 to 64 mg/L, Low- Request that pool operators check pool balance and increase Alkalinity levels, maintain between 80 and 120 mg/L.ORP = 777mV
  10. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • - Main pool had elevated/high levels of HPC in water sample. Discussed with pool operator at this time, requested he check main pool disinfection system and pool chemistry balance again.
  11. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • - Main pool had elevated levels of HPC in water sample. Discussed with pool operator at this time, requested he check main pool disinfection system and pool chemistry balance at this time.
  12. Demand Inspection

    0 infractions

  13. Risk Management Inspection

    0 infractions

  14. Monitoring Inspection

    0 infractions