Skip to content
Loading map…

Charltons Banff - Swimming Pool

513 Banff Avenue Banff AB T1L 1B4 · Aquatic Facility

12 inspections

  1. Demand Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday May 25th, 2026, had a HPC of 360 cfu/ml. Operators were informed to treat and re-sample.
  3. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday May 11th, 2026, was not processed by the lab. Missing date of collection on the form, operators were informed to submit a re-sample.
  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday March 23rd, 2026, had an HPC of 150 CFU/ml. - Operators were informed to treat and submit a re-sample.
  5. Risk Management Inspection

    0 infractions

  6. Monitoring Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Dec.29/25; Sample not tested, no time on label.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Main drain cover has been changed; anti-entrapment plan has not been updated, and new cover specifications were not available onsite. - Please update anti-entrapment plans to indicate the new covers. Perform new anti-entrapment assessment.
  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Dec.29/25; Sample not tested, no time on label.
  8. Monitoring Inspection

    0 infractions

  9. Demand Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from March 18th, 2024, was not processed by the lab due to a missing ID number on the bottle.- Operators were informed to submit a re-sample on Thursday.
  11. Monitoring Inspection

    0 infractions

  12. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Dec.29/22; No sample submitted this week; sample on Dec.29 was not taken to lab as there was no courier.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Jul 31/23; Sample not tested no id label on bottle.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow meter on the swimming pool’s plumbing read ~ 80 GPM. The TR-100 filter’s max flow rate is only 74 GPM. To ensure the water is effectively filtered, please lower the flow rate going through the swimming pool's filter at or below 74 GPM.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • The anti-entrapment was reviewed and it was incomplete. Please revise the anti-entrapment plan and resubmit the plan. Facility may consult a pool company or engineer if onsite pool operators are unfamiliar with the plumbing.