Checkmate Hill - Swimming Pool
103 - 4902 37 Street Red Deer AB T4N 6M9 · Aquatic Facility
14 inspections
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Tested readings: Total Alkalinity - 56 ppmCombined Chlorine - 0.75 ppm
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Total coliforms were detected in the water sample collected on January 16, 2026.The PHI emailed and discussed the results with the CPO.The CPO confirmed that the pool would be shocked, water chemistry rebalanced, and a follow-up water sample submitted.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Tested readings: Total Alkalinity - 56 ppmCombined Chlorine - 0.75 ppm
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Tested readings: Total Alkalinity - 56 ppmCombined Chlorine - 0.75 ppm
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Total coliforms were detected in the water sample collected on January 5, 2026.The PHI emailed and discussed the results with the CPO.The CPO confirmed that the pool would be shocked, water chemistry rebalanced, and a follow-up water sample submitted.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Tested readings: Total Alkalinity - 56 ppmCombined Chlorine - 0.75 ppm
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Tested readings: Total Alkalinity - 56 ppmCombined Chlorine - 0.75 ppm
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Total coliforms present in water sample collected on June 9, 2025.PHI emailed and discussed with CPO.CPO confirmed that he would shock the pool, rebalance the water and submit another sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Tested readings: Total Alkalinity - 56 ppmCombined Chlorine - 0.75 ppm
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Total coliforms present in water sample collected on June 9, 2025.PHI emailed and discussed with CPO.CPO confirmed that he would shock the pool, rebalance the water and submit another sample.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- PHI water sampling test kit, showed that the FAC: 1.89 ppmpH: 8.01, this is greater than the minimum requirement of 7.6.TC: 2.19 ppmAlkalinity: 160
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- PHI water sampling test kit, showed that the FAC: 1.89 ppmpH: 8.01, this is greater than the minimum requirement of 7.6.TC: 2.19 ppmAlkalinity: 160
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on May 21, 2024, has total coliforms present. Please super-chlorinate the swimming pool and submit a resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on May 21, 2024, has a heterotrophic plate count of 160 CFU/mL. Please ensure that the pool water is resampled.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The bacteriological water sample collected on April 17, 2024, has total coliforms present. Please super-chlorinate the pool and submit a resample next week.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory sample results.HPC=410Operator to raise chlorine levels and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?