Skip to content
Loading map…

Country View Motel & R.V. Park Camping Resort

4569 London Line, Wyoming ON N0N 1T0 · Seasonal Class B Public Pool

Inspection summary

Country View Motel & R.V. Park Camping Resort has been inspected 7 times by Lambton Public Health since June 11, 2025. The most recent inspection, on August 19, 2026, recorded 1 infraction.

3 of 7 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 4 times across 3 separate inspections, most recently on July 6, 2026. For example: Where cyanurate stabilization is maintained in outdoor pools, free available chlorine (FAC) reads a minimum of 1.0 ppm and not more than 10 ppm, in association with a cyanuric acid concentration of not greater than 60 ppm.

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 2 times across 2 separate inspections, most recently on August 19, 2026. For example: Operator kept and signed daily records. Records are retained for a period of 1 year.

About this data

These results come from Lambton Public Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

7 inspections

  1. Required

    1 infraction

    • Operator kept and signed daily records. Records are retained for a period of 1 year.
      • Fail to record the reading of the make-up water meter at the end of the day.
      • Fail to record the results of the tests required under subsections 7(11) and 7(12) of the Regulation (i.e. TA, pH, FAC, TC, Br, water clarity, water temperature) every 2 hrs (without an automatic sensing device) or every 4 hrs (with an automatic sensing device).
  2. Follow-up

    0 infractions

  3. Follow-up

    1 infraction

    • Where cyanurate stabilization is maintained in outdoor pools, free available chlorine (FAC) reads a minimum of 1.0 ppm and not more than 10 ppm, in association with a cyanuric acid concentration of not greater than 60 ppm.
      • Fail to maintain stabilized FAC at 1.0 - 10 ppm. Close pool.
  4. Follow-up

    2 infractions

    • Where cyanurate stabilization is maintained in outdoor pools, free available chlorine (FAC) reads a minimum of 1.0 ppm and not more than 10 ppm, in association with a cyanuric acid concentration of not greater than 60 ppm.
    • Written emergency and operational procedures and instructions are available at the pool to be implemented in the event of an emergency, accident or injury in the pool.
  5. Follow-up

    0 infractions

  6. Required

    2 infractions

    • Where cyanurate stabilization is maintained in outdoor pools, free available chlorine (FAC) reads a minimum of 1.0 ppm and not more than 10 ppm, in association with a cyanuric acid concentration of not greater than 60 ppm.
      • Fail to maintain stabilized FAC at 1.0 - 10 ppm. Close pool.
    • Operator kept and signed daily records. Records are retained for a period of 1 year.
      • Fail to record the estimated number of bather uses during the operating day.
      • Fail to record the reading of the make-up water meter at the end of the day.
      • Fail to record the results of the tests required under subsections 7(11) and 7(12) of the Regulation (i.e. TA, pH, FAC, TC, Br, water clarity, water temperature) every 2 hrs (without an automatic sensing device) or every 4 hrs (with an automatic sensing device).
      • Fail to record the time of day the emergency telephone was tested to confirm that the system is in operating condition.
      • Fail to ensure all records are completed and signed by operator.
  7. Required

    0 infractions

Nearby inspected facilities