Skip to content
Loading map…

Dickson RV Resort - Pool

35342 Range Road 25 Red Deer County AB T4G 0N3 · Aquatic Facility

9 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Routine water sample result: HPC – 250 CFU/mlPlease review recent water chemistry records to ensure pH and Free Chlorine levels have been maintained. Ensure both are within the required limits. There has been a lot of rain recently which could affect the water chemistry of an outdoor pool.Resample on your regular sampling day
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. Routine water sample result: TC PresentPlease resample to confirm test result. Make sure to mark the bottle as "Resample".
  5. Monitoring Inspection

    0 infractions

  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Routine water sample result: HPC 250.Resample to confirm result.Review water chemistry to confirm free chlorine and pH are within specifications.
  8. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Water ChemistryCC .16Alk 53The pool had just been recommissioned after winter hiatus and water chemistry was still being adjusted.
  9. Monitoring Inspection

    0 infractions