- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Bacteriological sample results taken 22 April 2026 returned indicating HPC > 57000Correction:- Close whirlpool access until a satisfactory HPC result has been returned- Utilize Heterotrophic plate count (HPC) exceedance treatment protocol:1. Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.2. Run the water through the circulation system for at least 4-6 hours. 3. Adjust water chemistry to regular operating parameters.4. Take a bacteriological water sample and send it to the lab.5. Reopen the pool to the public when instructed by your public health inspector.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample results from the Provincial Laboratory indicated a Heterotrophic Plate Count (HPC) of 160 CFU per 100 mL of the whirlpool water sample submitted on February 10, 2025.Ensure that the pool's bacteriological water quality is compliant, and that the tested HPC value does not exceed 100 CFU.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Violation document on October 30, 2024: - Whirlpool Alkalinity was measured in exceedance of 200 ppm, and could not be properly measured. - White "Scaling" was observed on the whirlpool basin and tiles.Correction:- Adjust the whirlpool alkalinity to a concentration no greater than 180 ppm
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- - Whirlpool Alkalinity was measured in exceedance of 200 ppm, and could not be properly measured. - White "Scaling" was observed on the whirlpool basin and tiles.Correction:- Adjust the whirlpool alkalinity to a concentration no greater than 180 ppm
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological water sample collected 18 March 2024 returned positive for the presence of total coliforms.Correction:- Observed total coliform response protocol- Submit a re-sample following protocol
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions