Holiday Inn Express Candlewood Suites West Edmonton - Swimming Pool
18520 100 Avenue NW Edmonton AB T5S 0K6 · Aquatic Facility
8 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on Feb. 5, 2026, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate was observed to be at 85 GPM.Pool Volume: 12060 GallonsFilter area: 4.91 sq ftFiltration rate: 17.3 gpm/sq ftThe maximum rate of filtration for a high-rate sand filter must not be greater than 10 LPS/sq m (15 gpm/sq ft) for swimming pools.Based on the system specs, ensure your flow rate is maintained in between 50 to 73 GPM to ensure proper filtration rate (and recirculation rate / turnover).
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- An up-to-date anti-entrapment plan was not available.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Debris build up inside the flowmeter was noted. Found difficulty in taking flow reading. Service the flowmeter.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Dec 07; Combined chlorine was measured to be 2.14ppm. Decreased combine chlorine and ensure it is below 1.0ppm to ensure bather comfort.Jan 19: Combined chlorine was measured to be 1.42ppm. Decreased combine chlorine and ensure it is below 1.0ppm to ensure bather comfort.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?