Holiday Inn Express Candlewood Suites West Edmonton - Whirlpool

18520 100 Avenue NW Edmonton AB T5S 0K6 · Aquatic Facility

16 inspections

  1. Monitoring Inspection

    0 infractions

  2. Risk Management Inspection

    0 infractions

  3. Risk Management Inspection

    2 infractions

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The max flow rate for the two Paramount SDX2 wall mounted suction outlet covers is 140GPM and the max flow rate on the system is 170GPM. Flow reading with the jets on read onsite was 150GPM. Option 1: Install suction outlet covers rated for >170GPM or Option 2: Install a flow secure system that ensures the flow is maintained below 140GPM. The jets must remain non-operational until anti-entrapment requirements are met.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An updated anti-entrapment plan was provided for the whirlpool. The wall mounted Paramount SDX2 covers (x2) were rated for a max system flow of 140GPM. Max flow based on the pump curve is 170GPM.
  4. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow meter for the jet pump was not operational. A new flow meter was on order.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An up-to-date anti-entrapment plan was not available.
  5. Risk Management Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity: 00 ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Automated controller pH reading 7.2 Manual pH reading 6.8.Discrepancies were noted among the automated controller reading and manual test results for pH.Investigate and service the probes if needed.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The wall clock by the whirlpool was not functional.Ensure the clock is functioning properly.
  6. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 21/02/2025 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity: 00 ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Automated controller pH reading 7.2 Manual pH reading 6.8.Discrepancies were noted among the automated controller reading and manual test results for pH.Investigate and service the probes if needed.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The wall clock by the whirlpool was not functional.Ensure the clock is functioning properly.
  7. Risk Management Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity: 00 ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Automated controller pH reading 7.2 Manual pH reading 6.8.Discrepancies were noted among the automated controller reading and manual test results for pH.Investigate and service the probes if needed.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The wall clock by the whirlpool was not functional.Ensure the clock is functioning properly.
  8. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on November 8, 2024, was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity: 00 ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Automated controller pH reading 7.2 Manual pH reading 6.8.Discrepancies were noted among the automated controller reading and manual test results for pH.Investigate and service the probes if needed.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The wall clock by the whirlpool was not functional.Ensure the clock is functioning properly.
  9. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total Alkalinity: 00 ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Automated controller pH reading 7.2 Manual pH reading 6.8.Discrepancies were noted among the automated controller reading and manual test results for pH.Investigate and service the probes if needed.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The wall clock by the whirlpool was not functional.Ensure the clock is functioning properly.
  10. Risk Management Inspection

    0 infractions

  11. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The sample submitted on 21 Mar 2024, was unsatisfactory: pseudomonas isolated . Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  12. Risk Management Inspection

    0 infractions

  13. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH of the pool water was 7.77Adjust the pH before opening the pool for comfort of bather.
  14. Risk Management Inspection

    0 infractions

  15. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 2023-07-20 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  16. Risk Management Inspection

    0 infractions