Holiday Inn Express & Suites Airdrie - Swimming Pool has been inspected 19 times by Alberta Health Services (Environmental Public Health) since June 27, 2024. The most recent inspection, on October 9, 2026, recorded 1 infraction.

6 of 19 inspections on record found no infractions at all. In the past 12 months there were 12 inspections with 9 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 12 times across 11 separate inspections, most recently on October 9, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 3 times across 3 separate inspections, most recently on October 3, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

19 inspections

  1. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on October 6, 2026 indicated a HPC count of 57,000 CFU/ml.Treat and resample pool.
  2. Risk Management Inspection

    0 infractions

  3. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted to the lab on Sept 22, 2026 was dated Sept 15th, 2026, which is more than 24 hours since collection. Water sample was not processed.**Resubmit sample
  4. Risk Management Inspection

    0 infractions

  5. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample submitted on Aug 18th was not processed due to a missing ID number.**Resubmit sample
  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample submitted on July 14th, 2026 was positive for Total Coliforms.**Complete treatment of the pool and resubmit sample to the lab.
  8. Monitoring Inspection

    0 infractions

  9. Demand Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The drain covers for the suction outlets in the swimming pool were expired.**Please install new drain covers and ensue drain covers are installed and used as per manufacturer's instructions.**Update and resend anti-entrapment plan following installation and email updated copy to PHI.
  10. Risk Management Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The drain covers for the suction outlets in the swimming pool were expired.**Please install new drain covers and ensue drain covers are installed and used as per manufacturer's instructions.**Update and resend anti-entrapment plan following installation and email updated copy to PHI.
  11. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on Jan 27th was not processed because time of collection was not indicated on the bottle.**Resubmit sample
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The drain covers for the suction outlets in the swimming pool were expired.**Please install new drain covers and ensue drain covers are installed and used as per manufacturer's instructions.**Update and resend anti-entrapment plan following installation and email updated copy to PHI.
  12. Monitoring Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The drain covers for the suction outlets in the swimming pool were expired.**Please install new drain covers and ensue drain covers are installed and used as per manufacturer's instructions.**Update and resend anti-entrapment plan following installation and email updated copy to PHI.
  13. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample received more than 24hours after collection was not processed.**Resubmit sample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Combined chlorine for the pool was measured at 1.55ppm**Please maintain CC value as low as possible**It is recommended to maintain combined chlorine value below 1.0ppm.
  14. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Combined chlorine for the pool was measured at 1.55ppm**Please maintain CC value as low as possible**It is recommended to maintain combined chlorine value below 1.0ppm.
  15. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Combined chlorine for the pool was measured at 1.68ppm**Please maintain CC value as low as possible**It is recommended to maintain combined chlorine value below 1.0ppm.
  16. Monitoring Inspection

    0 infractions

  17. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on Sept 3, 2024 indicated a HPC count of 550 CFU/ml.Treat and resample pool.
  18. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on July 23, 2024 indicated a HPC count of 110 CFU/ml.Treat and resample pool.
  19. Initial Inspection

    0 infractions

Nearby inspected facilities