Holiday Inn Lethbridge - Pool
2375 Mayor Magrath Drive S Lethbridge AB T1K 7M1 · Aquatic Facility
Inspection summary
Holiday Inn Lethbridge - Pool has been inspected 35 times by Alberta Health Services (Environmental Public Health) since October 23, 2023. The most recent inspection, on September 8, 2026, recorded 1 infraction.
1 of 35 inspections on record found no infractions at all. In the past 12 months there were 11 inspections with 17 infractions recorded. The higher-risk findings here relate to: Chemicals and toxic substances, Pool and spa water quality and Food temperature control.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 25 times across 25 separate inspections, most recently on September 8, 2026. For example:
Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 16 times across 16 separate inspections, most recently on August 28, 2026. For example:
Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
Food temperature controlHigher risk
Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.
Recorded 9 times across 9 separate inspections, most recently on May 9, 2024. For example:
Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
35 inspections
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 620 CFU/mL was isolated in the sample collected August 25. An HPC of 380 CFU/mL was isolated in the sample collected August 18.Please address the HPC in the pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 380 cfu/mL
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 2290 CFU/mL was isolated in the sample collected June 9.Please address the HPC in the pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 8480 CFU/mL was isolated in the sample collected April 7. Please address the HPC in the pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 6600 CFU/mL was isolated in the sample collected March 24.An HPC of 8500 CFU/mL was isolated in the sample collected March 17. Please address the HPC in the pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 8500 CFU/mL was isolated in the sample collected March 17. Please address the HPC in the pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 57 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be assessed again during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 460 CFU/mL in July 22 sample. Please address the HPC in the pool and submit a resample once complete.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine was less today than during the last visit but was still a bit high at 1.10 ppm. For bather comfort, this level should be kept as low as possible and at least below 1.0 ppm. The pool may need to be shocked to bring this value down.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 320 CFU/mL
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine was less today than during the last visit but was still a bit high at 1.10 ppm. For bather comfort, this level should be kept as low as possible and at least below 1.0 ppm. The pool may need to be shocked to bring this value down.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine was less today than during the last visit but was still a bit high at 1.10 ppm. For bather comfort, this level should be kept as low as possible and at least below 1.0 ppm. The pool may need to be shocked to bring this value down.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine was measured to be 1.43 ppm. For bather comfort, this level should be kept as low as possible and at least below 1.0 ppm. The pool may need to be shocked to bring this value down.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 140 CFU/mL was isolated in the sample collected September 9. Please address the HPC in the pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of >57000 CFU/mL was isolated in the sample collected July 30. Please address the HPC in the pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 1450 CFU/ml
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of >57000 CFU/mL was isolated in the sample collected May 29. Please address the HPC in the wave pool and submit a resample once complete.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. Alkalinity will be checked during the next routine inspection.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The alkalinity was measured to be 45 ppm. Please ensure that the alkalinity is maintained between 60-180 ppm at all times.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The cover for the floor inlet located in the small square area to the left of the waterslide entry was loose and coming off of the inlet. It swung to the side exposing a pipe opening in the floor. This was discussed with the operator. Please ensure any large floor inlets have appropriate covers on them.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There were quite a few spots of chipping on the bottom of the pool basin. Some of these spots were quite large with rough edges. These areas were discussed with the pool operator who indicated that they had a plan to fix them, they just need a quiet time (ie. hotel booking) to do it as it requires the draining of the pool. They are aiming to complete the work at the end of December/beginning of January.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 140 CFU/mL was isolated in the sample collected April 9.Please address the HPC in the pool and submit a resample once complete.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There were quite a few spots of chipping on the bottom of the pool basin. Some of these spots were quite large with rough edges. These areas were discussed with the pool operator who indicated that they had a plan to fix them, they just need a quiet time (ie. hotel booking) to do it as it requires the draining of the pool. They are aiming to complete the work at the end of December/beginning of January.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There were quite a few spots of chipping on the bottom of the pool basin. Some of these spots were quite large with rough edges. These areas were discussed with the pool operator who indicated that they had a plan to fix them, they just need a quiet time (ie. hotel booking) to do it as it requires the draining of the pool. They are aiming to complete the work at the end of December/beginning of January.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 1620 CFU/mL was isolated in the sample collected March 19. An HPC of 360 CFU/mL was isolated in the sample collected March 12. Please address the HPC in the pool and submit a resample once complete.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There were quite a few spots of chipping on the bottom of the pool basin. Some of these spots were quite large with rough edges. These areas were discussed with the pool operator who indicated that they had a plan to fix them, they just need a quiet time (ie. hotel booking) to do it as it requires the draining of the pool. They are aiming to complete the work at the end of December/beginning of January.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 360 CFU/mL was isolated in the sample collected March 12. Please address the HPC in the pool and submit a resample once complete.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There were quite a few spots of chipping on the bottom of the pool basin. Some of these spots were quite large with rough edges. These areas were discussed with the pool operator who indicated that they had a plan to fix them, they just need a quiet time (ie. hotel booking) to do it as it requires the draining of the pool. They are aiming to complete the work at the end of December/beginning of January.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There were quite a few spots of chipping on the bottom of the pool basin. Some of these spots were quite large with rough edges. These areas were discussed with the pool operator who indicated that they had a plan to fix them, they just need a quiet time (ie. hotel booking) to do it as it requires the draining of the pool. They are aiming to complete the work at the end of December/beginning of January.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- An HPC of 700 CFU/mL was found in the sample collected Oct 24/23. Please shock the pool and submit a resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There were quite a few spots of chipping on the bottom of the pool basin. Some of these spots were quite large with rough edges. These areas were discussed with the pool operator who indicated that they had a plan to fix them, they just need a quiet time (ie. hotel booking) to do it as it requires the draining of the pool. They are aiming to complete the work at the end of December/beginning of January.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There were quite a few spots of chipping on the bottom of the pool basin. Some of these spots were quite large with rough edges. These areas were discussed with the pool operator who indicated that they had a plan to fix them, they just need a quiet time (ie. hotel booking) to do it as it requires the draining of the pool. They are aiming to complete the work at the end of December/beginning of January.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
Nearby inspected facilities
- Holiday Inn Lethbridge - Whirlpool
2375 Mayor Magrath Drive S Lethbridge AB T1K 7M1
20 inspections
- Holiday Inn Lethbridge - Kids Pool
2375 Mayor Magrath Drive S Lethbridge AB T1K 7M1
14 inspections
- Holiday Inn Lethbridge - Common area
2375 Mayor Magrath Drive S Lethbridge AB T1K 7M1
5 inspections
- SureStay Plus By Bestwestern - Whirlpool
2225 Mayor Magrath Drive S Lethbridge AB T1K 7M1
9 inspections
- SureStay Plus By Best Western Lethbridge 53028 - Food
2225 Mayor Magrath Drive S Lethbridge AB T1K 7M1
5 inspections
- RONA 66190
2260 32 Street S Lethbridge AB T1K 7T9
1 inspection
- Burger King 11896
2416 Fairway Plaza Road S Lethbridge AB T1K 6Z3
6 inspections
- Wild Bros Meat & Cheese
101 - 2049 Mayor Magrath Drive S Lethbridge AB T1K 2S2
5 inspections