Holiday Inn & Suites - Hot Tub

33 Petrolia Drive County Of Red Deer AB T4E 1B3 · Aquatic Facility

16 inspections

  1. Risk Management Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Initial test results:pH = 7.15Total Alkalinity = 48 ppmFAC = 0.56 mg/LTC = 1.92 mg/LTemperature = 40.8°CORP = 733 mVPool operator was asked to adjust the water chemistry during the inspection as alkalinity was not in the required range of 60 to 180ppm.Following adjustment by the pool operator, FAC = 1.24 mg/LTC = 2.22 mg/LTotal Alkalinity = 125 ppm ORP = 740 mV were recorded.Water chemistry was adjusted and operating parameters were within acceptable ranges at the time of re-inspection.Ensure water chemistry is maintained within required operating parameters, including free chlorine residual ≥0.5 mg/L, ORP ≥700 mV, pH ≤7.3, and total alkalinity between 60 and 180 ppm, to support effective disinfection and safe operation of the whirlpool.
  2. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Initial test results:FAC= 7.82 mg/LTC= OR (Over Range)CC = Could not CalculatepH =7.57Temp = 39.6°Cwater = clarity satisfactory.CDI: Due to the elevated chlorine residual, the operator was asked to adjust the water chemistry. After adding Aqua Balance,FAC = 0.78 mg/LORP = 646 mV (from controller)Following further adjustment:FAC = 0.70 mg/LORP = 634 mV (from controller)The operator voluntarily agreed to close the whirlpool, and front desk staff were preparing a "Do Not Use" sign.Free chlorine residual was measured below the minimum required 2.0 mg/L and ORP was below the recommended minimum 700 mV for a whirlpool operating at 39.6°C.Ensure free chlorine residual is maintained at a minimum of 2.0 mg/L and ORP is maintained at 700 mV or greater to provide adequate disinfection and safe operation of the whirlpool.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Sand filters of pool: Pentair Tagelus TA 100DSurface area of filter: 4.91 sq.ftMaximum Filtration rate for filter: 80 GPMMaximum rate of filtration: 80GPM/4.91 sq.ft = 16.29 GPM/sq.ftThe calculated filtration rate of 16.29 GPM/sq. ft. exceeds the maximum allowable filtration rate of 12.5 GPM/sq. ft. for a whirlpool utilizing a high-rate sand filter constructed after November 2006.Ensure the filtration rate for the high-rate sand filter does not exceed 12.5 GPM/sq. ft. and that the filtration system is operated in accordance with the Pool Standards and approved design specifications.
  3. Risk Management Inspection

    0 infractions

  4. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH of the pool was measured to be 7.93, which exceeds the required range of 6.8-7.6. The operator was informed that the pH must be lowered. The operator stated that the whirlpool will be drained and that the pH concentration will be tested tomorrow morning. It was observed that the whirlpool was draining while during the inspection. Follow-up is required to ensure that the whirlpool pH is within an acceptable range.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample received:Total Coliforms - PRESENTHPC - not yet available Pseudomonas - not yet availablePlease shock chlorinate according to this procedure: wf-eph-interpret-microbiological-sample-results-pools.pdf
  7. Risk Management Inspection

    0 infractions

  8. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free chlorine: 1.24 ppm**Please ensure the free chlorine levels are maintained at 2 ppm or above for the hot tub.-The operator indicated that the basin will be drained, cleaned and water chemistry balanced.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • PHI observed a constant value of 0.4ppm for combined chlorine in the water testing records.**Please ensure proper testing and records are maintained for all water chemistry parameters.
  9. Monitoring Inspection

    0 infractions

  10. Risk Management Inspection

    0 infractions

  11. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The pool does not meet the required turnover period. The calculated turnover rate was 23mins. **Have the flow rate adjusted to ensure a required minimum turnover rate of 15 mins is achieved.
  12. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The measured pH=7.88.**Please have the water chemistry balanced to ensure the pool water is maintained within a pH range of 6.8-7.6
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The pool does not meet the required turnover period. The calculated turnover rate was 23mins. **Have the flow rate adjusted to ensure a required minimum turnover rate of 15 mins is achieved.
  13. Risk Management Inspection

    0 infractions

  14. Demand Inspection

    0 infractions

  15. Risk Management Inspection

    0 infractions

  16. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on September 11, 2023Pseudomonas aeruginosa= Isolated per 100ml.**Operator to shock chlorinate and resample