Skip to content
Loading map…

Jessica Beauty Salon & Spa Inc.

3-7171 Goreway Dr Mississauga ON L4T 2T5 · Micropigmentation

2 inspections

  1. Required

    2 infractions

    • Did operator meet requirements for equipment that is used in invasive services?
      • Provide manufacturer documentation that equipment purchased is sterile and states the method used for sterilization (e.g., E.O. gas, gamma ray).
      • The needle cartridge system must have proof from the manufacturer that it has a backflow preventer/protective membrane.
      • Ensure equipment is not used beyond the expiry date provided by the manufacturer. Expired items must be discarded appropriately.
    • Did operator properly use and maintain cleaning and disinfecting products?
  2. Required

    3 infractions

    • Did operator properly disinfect equipment and surfaces?
      • Disinfect reusable equipment after use on a client to prevent disease transmission.
      • Disinfect reusable equipment with appropriate disinfectant required for the equipment.
      • Fully immerse reusable equipment in the disinfectant.
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Intermediate-level disinfect equipment such as nail clippers, cuticle nippers, nail drill bits, ear piercing device, single-use ink caps, tweezers and scissors used in hair removal services.
      • Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
      • Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
    • Did operator properly use and maintain cleaning and disinfecting products?
    • Did operator maintain client records for invasive services?
      • Observed incomplete records.
      • Keep records for invasive procedures including, which procedure was done and the part of the body the procedure was done to, client name and contact information, service provider name and contact information, explanation of and risks associated with the procedure, date of procedure and lot numbers and expiry date of the pre-packaged sterile equipment used in the procedure. (Show More)
      • In the client record, document lot number and expiry date of the pre-packaged sterile equipment used in the procedure.
      • Before starting the procedure, provide clients with an explanation of and risks associated with the invasive procedure.
      • In the client record, make note of when you explain the service and any risks associated with the service to the client.
      • Keep invasive procedure records for one year at personal service setting and readily available for an additional two years.
      • Provide records to a medical officer of health or public health inspector on request.
      • Records must be made by the operator or personal service worker who provided the explanation and information of the invasive procedure.
      • Provide clients with verbal and written after-care instructions for invasive and laser services.