K S Julie Hair Design, Esthetics & Fitness Centre

231 - 328 Centre Street SE Calgary AB T2G 4X6 · Personal Services

Inspection summary

K S Julie Hair Design, Esthetics & Fitness Centre has been inspected 2 times by Alberta Health Services (Environmental Public Health) since September 3, 2025. The most recent inspection, on September 21, 2025, found no infractions.

1 of 2 inspections on record found no infractions at all. No inspections are on record from the past 12 months. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 2 times on September 3, 2025. For example: Is reusable equipment handled and stored properly (Critical)?

  • Permits, records and postingLower risk

    Operating permits, client records, sterilization logs and required signage. Client records matter because they let health officials contact people if an infection is linked to the business.

    Recorded once on September 3, 2025. For example: Are facility-specific written procedures established to adequately describe safe and sanitary practices?

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded once on September 3, 2025. For example: Are sinks accessible and used appropriately for the personal services provided?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

2 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    4 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • The operator is using the sink in the service room to perform hand hygiene and to reprocess semi-critical tools. There are no written procedures for decontamination of a dual-purpose sink. Written procedures are required for decontamination of a dual-purpose sink. An AHS template was provided to the operator.
    • 15. Is reusable equipment handled and stored properly (Critical)?
      • After the semi-critical tools (comodone extractor) is disinfected, the operator is placing it in a small jar and the equipment is exposed to potential contamination (dust/debris). Reusable tools must be stored in a manner that protects it from contamination. Cover the tools to protect it from contamination or place the tools inside a clean container.
    • 20. Is reusable equipment disinfected properly?
      • 1. The operator is using alcohol to disinfect non-critical tools (the head piece of the high frequency equipment). Alcohol is not considered a disinfectant. Use a low-level or intermediate level disinfectant for non-critical devices. 2. The operator disinfects the semi-critical tool (comodone extractor) with the high-level disinfectant, then places it in alcohol. For semi-critical tools, use a high-level disinfectant and ensure the manufacturer's instructions are followed accordingly.3. There is tape used to cover the hand piece of the high-frequency equipment. The operator stated the equipment is not broken. The tape is used to prevent water from going down the hand piece. Tape should not be used as it does not allow proper cleaning and disinfection for non-critical tools and equipment. Remove the tape.
    • 31. Are sinks accessible and used appropriately for the personal services provided?
      • The hand sink was not equipped with paper towels to dry the hands. Paper towels must be placed at the hand sink to perform proper hand hygiene. Please install.