Lake Louise Inn - Upper Right Whirlpool
210 Village Road Lake Louise AB · Aquatic Facility
9 inspections
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Oct.29/25; Sample not tested no date on requisition.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- May 5/26; Sample not tested; no id label on bottle.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Gauge on filter is broken/filled with water. To adequately assess any fluctuations in filter pressure for backwashing/maintenance, ensure gauge is repaired.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Oct.29/25; Sample not tested no date on requisition.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Gauge on filter is broken/filled with water. To adequately assess any fluctuations in filter pressure for backwashing/maintenance, ensure gauge is repaired.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Gauge on filter is broken/filled with water. To adequately assess any fluctuations in filter pressure for backwashing/maintenance, ensure gauge is repaired.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Dec.3/24 Sample had elevated HPC of 160cfu/ml. Treat and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity measured at 15ppm. To ensure pH is stable, alkalinity must be between 60 and 180ppm.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from7/23/2024 was not processed by the lab, missing ID sticker on the bottle. - Operators were informed to submit a re-sample.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Please update anti-entrapment plan with up-to-date drain cover information (currently indicates one set due to be changed 2021, but some covers may have already been changed.).
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Please update anti-entrapment plan with up-to-date drain cover information (currently indicates one set due to be changed 2021, but some covers may have already been changed.).
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Demand Inspection
4 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC of 1560 CFU/ml was detected in the April 4, 2023 water sample. Operator was asked to treat the basin.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- July 28/23; HPC of 1020cfu/ml. Treat to 10ppm chlorine and check all systems working.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- October 24/23; Sample had an HPC of 450cfu/ml. Treat to 10ppm chlorine and resample.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Please update anti-entrapment plan with up-to-date drain cover information (currently indicates one set due to be changed 2021, but some covers may have already been changed.).
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC of 1560 CFU/ml was detected in the April 4, 2023 water sample. Operator was asked to treat the basin.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- July 28/23; HPC of 1020cfu/ml. Treat to 10ppm chlorine and check all systems working.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Please update anti-entrapment plan with up-to-date drain cover information (currently indicates one set due to be changed 2021, but some covers may have already been changed.).
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?