Skip to content
Loading map…

L'Hermitage - Outdoor Pool

788 Richards St, Vancouver BC V6B 3A4 · Pool

Inspection summary

L'Hermitage - Outdoor Pool has been inspected 24 times by Vancouver Coastal Health since June 22, 2015. The most recent inspection, on November 21, 2025, found no infractions.

8 of 24 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 35 times across 16 separate inspections, most recently on November 17, 2025. For example: The pool pH level is properly maintained

  • Equipment and utensilsLower risk

    Pumps, filters, chemical feeders and safety equipment such as lifebuoys, reaching poles and first-aid kits must be present and working. Missing safety equipment can matter a great deal in an emergency.

    Recorded 5 times across 4 separate inspections, most recently on August 14, 2024. For example: Adequate safety equipment is provided

About this data

These results come from Vancouver Coastal Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

24 inspections

  1. Routine Follow-up

    0 infractions

  2. Routine

    1 infraction

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
  3. Routine

    0 infractions

  4. Routine Follow-up

    0 infractions

  5. Routine

    4 infractions

    • Pool water velocity and recirculation rate is properly maintained
    • Adequate safety equipment is provided
      • Pool is not equipped with a throwing ring and/or the rope for the ring is not at least ½ the width of the pool plus 3 metres (N/A for pools < 10m²)
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  6. Routine

    0 infractions

  7. Routine Follow-up

    0 infractions

  8. Routine

    2 infractions

    • Adequate safety equipment is provided
      • Pool is not equipped with a throwing ring and/or the rope for the ring is not at least ½ the width of the pool plus 3 metres (N/A for pools < 10m²)
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
      • Required pool records are not available on request by a health officer
  9. Routine Follow-up

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  10. Routine

    4 infractions

    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • The operator maintains the pool in good repair.
      • Handrails at steps, ladders and diving boards are not secure.
  11. Routine Follow-up

    0 infractions

  12. Routine

    5 infractions

    • The pool is operated in accordance with the terms and conditions of the permit
    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • The pool chemical test kit is absent/not in good condition and/or cannot produce accurate readings for required chemical parameters.
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  13. Routine

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  14. Routine

    4 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • The operator maintains the pool in good repair.
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  15. Routine

    2 infractions

    • The pool pH level is properly maintained
    • Daily pool records are adequately maintained and available on site
  16. Routine

    4 infractions

    • The Permit to Operate a pool is valid and is posted in a prominent location.
    • The pool pH level is properly maintained
    • The pool alkalinity is properly maintained
    • Daily pool records are adequately maintained and available on site
  17. Routine

    2 infractions

    • The Permit to Operate a pool is valid and is posted in a prominent location.
    • Drinking water is reasonably accessible by pool patrons
  18. Routine

    2 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  19. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
  20. Routine Follow-up

    0 infractions

  21. Routine

    2 infractions

    • The pool cyanuric acid stabilizer level is properly maintained
      • The cyanuric acid stabilizer level is greater than 80 ppm
    • Daily pool records are adequately maintained and available on site
      • Results of daily water testing is inadequately recorded: Free Available Chlorine, Combined Available Chlorine and pH is tested and recorded at least twice daily; Alkalinity and Cyanuric Acid is tested and recorded at least weekly.
      • The amount and types of chemicals added to the pool water is inadequately recorded
  22. Routine

    0 infractions

  23. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
  24. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Pool rules are posted prominently within the pool enclosure