Skip to content
Loading map…

Observatory Ph 2 - YRCC 616

33 Weldrick Road East, Richmond Hill, ON L4C 8W4 · Class B, Whirlpool/Spa

Inspection summary

Observatory Ph 2 - YRCC 616 has been inspected 8 times by York Region Public Health since January 15, 2025. The most recent inspection, on September 22, 2026, found no infractions.

5 of 8 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 4 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 2 times on September 21, 2025. For example: Total alkalinity is within required range

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 2 times on May 13, 2026. For example: Daily records completed and signed

  • Building, plumbing and upkeepLower risk

    Decks, ladders, fencing, drains, washrooms and signage must be in good repair. Damaged drain covers or broken fencing can be real safety hazards, while most other upkeep issues are lower risk.

    Recorded once on September 21, 2025. For example: Water outlet covers are present, secure and in good repair

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded 5 times across 3 separate inspections, most recently on May 13, 2026. For example: Facility conducts required tests at appropriate intervals, as required

About this data

These results come from York Region Public Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

8 inspections

  1. Compliance Inspection

    0 infractions

  2. Compliance Inspection

    3 infractions

    • Facility conducts required tests at appropriate intervals, as required
      • Fail to check TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa, Hot Water Pool) at least every 4 hours during daily use period where automatic sensing device is used
    • Daily records completed and signed
      • Fail to record TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa, Hot Water Pool) at least every 4 hours during daily use period where automatic sensing device is used
    • Other tests and records completed and signed
      • Fail to ensure water, gravity, and suction outlet covers are inspected at least once in each 30 day operating period
      • Fail to ensure emergency stop button is tested at least once in each 30 day operating period
      • Fail to ensure vacuum release mechanism is tested and inspected at least once in each 30 day operating period
  3. Compliance Inspection

    1 infraction

    • Water heater equipped with an operational tamper-proof upper limit cut-off switch
      • Fail to ensure upper limit cut-off switch limits maximum temperature of water to 40°C (104°F)
  4. Compliance Inspection

    0 infractions

  5. Re-inspection

    0 infractions

  6. Compliance Inspection

    6 infractions

    • Total alkalinity is within required range
      • Fail to maintain total alkalinity in range of 60 - 180 ppm
    • pH is within required range
      • Fail to maintain pH within range of 7.2 to 7.8
    • Total bromine residual is within required range
      • Fail to maintain total bromine residual between 5 - 10 ppm (Spa, Wading Pool, Hot Water Pool)
    • Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
      • Fail to maintain ORP value between 600-900 mV
    • Water outlet covers are present, secure and in good repair
      • Fail to maintain water outlet covers in good repair
    • The premise appears to be free from conditions that might be a health hazard
      • Fail to maintain facility in safe condition
  7. Compliance Inspection

    0 infractions

  8. Compliance Inspection

    0 infractions