Pierre's Tattoos
277 Raglan St, Renfrew ON K7V 1R4 · Tattooing / Micropigmentation
4 inspections
- Required
1 infraction
- Equipment is maintained in good repair, sanitary condition and in accordance with the manufacturer’s instructions.
- Ensure equipment is maintained in accordance with the manufacturer’s instructions.
- Equipment is maintained in good repair, sanitary condition and in accordance with the manufacturer’s instructions.
- Required
2 infractions
- Floors, walls, ceiling, fixtures and furniture of the setting is in good repair, easily cleanable and maintained in a safe and sanitary condition.
- Ensure floors, walls, and ceilings are in good repair and are of a smooth and impermeable material and maintained in a sanitary condition.
- Disinfection records are kept.
- Ensure the name of the disinfectant utilized is recorded.
- Ensure the concentration of the disinfectant utilized is recorded.
- Ensure the date the disinfectant was prepared is recorded.
- Floors, walls, ceiling, fixtures and furniture of the setting is in good repair, easily cleanable and maintained in a safe and sanitary condition.
- Follow-up
0 infractions
- Required
4 infractions
- Reusable equipment is cleaned, and disinfected or sterilized as often as necessary.
- Reusable equipment must be cleaned and disinfected or sterilized between each use.
- Critical class instrument/equipment must be thoroughly cleaned and sterilized.
- Sterilizers meet the standards established by Health Canada and CSA.
- Ensure sterilizer is a commercially approved autoclave/dry heat sterilizer.
- Ensure use of sterilizers follow directions by a public health inspector.
- Ensure sterilizers in use are tested at least once every two weeks (with a biological indicator) to ensure that they are adequately destroying micro-organisms.
- Ensure spore strips must be sent to a laboratory after exposure to confirm the bacteria are destroyed.
- Ensure Manufacturer’s instructions for the sterilizer are followed.
- Do not use dishwashers, boiling, UV light or irradiation, glass bead sterilizers, microwave ovens, pressure cookers, flash sterilization, chemiclaves, or glutaraldehyde for sterilization.
- Ensure tests are run before putting a newly installed sterilizer to use; After relocating a sterilizer; After repairs that could affect the sterilizers performance; Mechanical malfunctions of the sterilizer; and After power outages or other emergency scenarios.
- Records are kept of invasive procedures.
- Ensure which procedure was done and on which part of the body is recorded.
- Ensure client records include the client name and contact information.
- Ensure the name and contact information of the service provider is recorded.
- Ensure the client was provided with an explanation of the procedure and information about any risks associated with the procedure and that this information is recorded.
- Ensure the procedure date is recorded.
- Ensure the lot numbers and expiry dates of sterile equipment are recorded.
- Ensure operator maintains records in a secure location onsite for one year and made available to a public heath inspector for two years afterwards.
- Sterilization records are kept.
- Ensure to record the name and type of sterilizer.
- Ensure to record date and time when the sterilizer was used.
- Ensure to record equipment on which the sterilizer was used.
- Record and maintain test results for chemical, physical and biological parameters.
- Ensure records are kept for maintenance or repairs of sterilizer.
- Ensure records are maintained of any preventative maintenance or repairs done on or to a sterilizer, and whether the sterilizer functioned properly after any maintenance or repairs.
- Ensure operator maintains records in a secure location onsite for one year and made available to a public heath inspector for two years afterwards.
- Reusable equipment is cleaned, and disinfected or sterilized as often as necessary.