Pierre's Tattoos

277 Raglan St, Renfrew ON K7V 1R4 · Tattooing / Micropigmentation

4 inspections

  1. Required

    1 infraction

    • Equipment is maintained in good repair, sanitary condition and in accordance with the manufacturer’s instructions.
      • Ensure equipment is maintained in accordance with the manufacturer’s instructions.
  2. Required

    2 infractions

    • Floors, walls, ceiling, fixtures and furniture of the setting is in good repair, easily cleanable and maintained in a safe and sanitary condition.
      • Ensure floors, walls, and ceilings are in good repair and are of a smooth and impermeable material and maintained in a sanitary condition.
    • Disinfection records are kept.
      • Ensure the name of the disinfectant utilized is recorded.
      • Ensure the concentration of the disinfectant utilized is recorded.
      • Ensure the date the disinfectant was prepared is recorded.
  3. Follow-up

    0 infractions

  4. Required

    4 infractions

    • Reusable equipment is cleaned, and disinfected or sterilized as often as necessary.
      • Reusable equipment must be cleaned and disinfected or sterilized between each use.
      • Critical class instrument/equipment must be thoroughly cleaned and sterilized.
    • Sterilizers meet the standards established by Health Canada and CSA.
      • Ensure sterilizer is a commercially approved autoclave/dry heat sterilizer.
      • Ensure use of sterilizers follow directions by a public health inspector.
      • Ensure sterilizers in use are tested at least once every two weeks (with a biological indicator) to ensure that they are adequately destroying micro-organisms.
      • Ensure spore strips must be sent to a laboratory after exposure to confirm the bacteria are destroyed.
      • Ensure Manufacturer’s instructions for the sterilizer are followed.
      • Do not use dishwashers, boiling, UV light or irradiation, glass bead sterilizers, microwave ovens, pressure cookers, flash sterilization, chemiclaves, or glutaraldehyde for sterilization.
      • Ensure tests are run before putting a newly installed sterilizer to use; After relocating a sterilizer; After repairs that could affect the sterilizers performance; Mechanical malfunctions of the sterilizer; and After power outages or other emergency scenarios.
    • Records are kept of invasive procedures.
      • Ensure which procedure was done and on which part of the body is recorded.
      • Ensure client records include the client name and contact information.
      • Ensure the name and contact information of the service provider is recorded.
      • Ensure the client was provided with an explanation of the procedure and information about any risks associated with the procedure and that this information is recorded.
      • Ensure the procedure date is recorded.
      • Ensure the lot numbers and expiry dates of sterile equipment are recorded.
      • Ensure operator maintains records in a secure location onsite for one year and made available to a public heath inspector for two years afterwards.
    • Sterilization records are kept.
      • Ensure to record the name and type of sterilizer.
      • Ensure to record date and time when the sterilizer was used.
      • Ensure to record equipment on which the sterilizer was used.
      • Record and maintain test results for chemical, physical and biological parameters.
      • Ensure records are kept for maintenance or repairs of sterilizer.
      • Ensure records are maintained of any preventative maintenance or repairs done on or to a sterilizer, and whether the sterilizer functioned properly after any maintenance or repairs.
      • Ensure operator maintains records in a secure location onsite for one year and made available to a public heath inspector for two years afterwards.