Sorrento Condo (The)

7 Bond Crescent, Richmond Hill, ON L4E 3K2 · Class B

9 inspections

  1. Compliance Inspection

    3 infractions

    • Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
      • Fail to maintain ORP value between 600-900 mV
    • Other tests and records completed and signed
      • Fail to ensure water, gravity, and suction outlet covers are inspected at least once in each 30 day operating period
      • Fail to test ground current leakage detecting and de-energizing device at least once monthly or according to manufacturer's instructions, whichever is more frequent
      • Fail to ensure emergency stop button is tested at least once in each 30 day operating period
      • Fail to ensure vacuum release mechanism is tested and inspected at least once in each 30 day operating period
    • Ground current leakage detecting and de-energizing device provided and functional where required
      • Fail to ensure ground current leakage detecting and de-energizing device is operational
  2. Compliance Inspection

    0 infractions

  3. Compliance Inspection

    1 infraction

    • Other tests and records completed and signed
      • Fail to ensure water, gravity, and suction outlet covers are inspected at least once in each 30 day operating period
      • Fail to test ground current leakage detecting and de-energizing device at least once monthly or according to manufacturer's instructions, whichever is more frequent
      • Fail to ensure emergency stop button is tested at least once in each 30 day operating period
      • Fail to ensure vacuum release mechanism is tested and inspected at least once in each 30 day operating period
  4. Re-inspection

    0 infractions

  5. Compliance Inspection

    8 infractions

    • pH is within required range
      • Fail to maintain pH within range of 7.2 to 7.8
    • Total bromine residual is within required range
      • Fail to maintain total bromine residual between 2 - 8 ppm (Pool, Cold Plunge Pool, Floatation Pool)
    • Water replacement carried out as required
    • Daily records completed and signed
      • Fail to record results of the emergency telephone test and time of day test was performed
      • Fail to record type and amount of any chemicals added manually to facility unit
    • Other tests and records completed and signed
      • Fail to test ground current leakage detecting and de-energizing device at least once monthly or according to manufacturer's instructions, whichever is more frequent
    • Operator is designated and trained
      • Fail to provide operator trained in recreational water facility operation and maintenance, filtration systems, water chemistry and all relevant safety and emergency procedures.
    • All components of the facility maintained in proper working order
      • Fail to ensure all components of the facility unit are maintained in proper working order
    • The premise appears to be free from conditions that might be a health hazard
      • Fail to maintain facility in safe condition
  6. Re-inspection

    0 infractions

  7. Compliance Inspection

    4 infractions

    • Total bromine residual is within required range
      • Fail to maintain total bromine residual of pool water between 2 - 8 mg/L
    • Water is maintained free from visible matter and contamination
      • Fail to maintain water free from visible matter that may be hazardous to bather health and safety
    • Other tests and records completed and signed
      • Fail to complete and sign records
    • The premise appears to be free from conditions that might be a health hazard
      • Fail to maintain facility in safe condition
      • Fail to maintain facility in sanitary condition
  8. Compliance Inspection

    1 infraction

    • Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
      • Fail to maintain ORP value between 600-900 mV
  9. Compliance Inspection

    2 infractions

    • Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
      • Fail to maintain ORP value between 600-900 mV
    • Facility conducts required tests at appropriate intervals, as required
      • Fail to manually test TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa) 30 minutes prior to opening