Sorrento Condo (The)
7 Bond Crescent, Richmond Hill, ON L4E 3K2 · Class B
9 inspections
- Compliance Inspection
3 infractions
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Fail to maintain ORP value between 600-900 mV
- Other tests and records completed and signed
- Fail to ensure water, gravity, and suction outlet covers are inspected at least once in each 30 day operating period
- Fail to test ground current leakage detecting and de-energizing device at least once monthly or according to manufacturer's instructions, whichever is more frequent
- Fail to ensure emergency stop button is tested at least once in each 30 day operating period
- Fail to ensure vacuum release mechanism is tested and inspected at least once in each 30 day operating period
- Ground current leakage detecting and de-energizing device provided and functional where required
- Fail to ensure ground current leakage detecting and de-energizing device is operational
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Compliance Inspection
0 infractions
- Compliance Inspection
1 infraction
- Other tests and records completed and signed
- Fail to ensure water, gravity, and suction outlet covers are inspected at least once in each 30 day operating period
- Fail to test ground current leakage detecting and de-energizing device at least once monthly or according to manufacturer's instructions, whichever is more frequent
- Fail to ensure emergency stop button is tested at least once in each 30 day operating period
- Fail to ensure vacuum release mechanism is tested and inspected at least once in each 30 day operating period
- Other tests and records completed and signed
- Re-inspection
0 infractions
- Compliance Inspection
8 infractions
- pH is within required range
- Fail to maintain pH within range of 7.2 to 7.8
- Total bromine residual is within required range
- Fail to maintain total bromine residual between 2 - 8 ppm (Pool, Cold Plunge Pool, Floatation Pool)
- Water replacement carried out as required
- Daily records completed and signed
- Fail to record results of the emergency telephone test and time of day test was performed
- Fail to record type and amount of any chemicals added manually to facility unit
- Other tests and records completed and signed
- Fail to test ground current leakage detecting and de-energizing device at least once monthly or according to manufacturer's instructions, whichever is more frequent
- Operator is designated and trained
- Fail to provide operator trained in recreational water facility operation and maintenance, filtration systems, water chemistry and all relevant safety and emergency procedures.
- All components of the facility maintained in proper working order
- Fail to ensure all components of the facility unit are maintained in proper working order
- The premise appears to be free from conditions that might be a health hazard
- Fail to maintain facility in safe condition
- pH is within required range
- Re-inspection
0 infractions
- Compliance Inspection
4 infractions
- Total bromine residual is within required range
- Fail to maintain total bromine residual of pool water between 2 - 8 mg/L
- Water is maintained free from visible matter and contamination
- Fail to maintain water free from visible matter that may be hazardous to bather health and safety
- Other tests and records completed and signed
- Fail to complete and sign records
- The premise appears to be free from conditions that might be a health hazard
- Fail to maintain facility in safe condition
- Fail to maintain facility in sanitary condition
- Total bromine residual is within required range
- Compliance Inspection
1 infraction
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Fail to maintain ORP value between 600-900 mV
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Compliance Inspection
2 infractions
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
- Fail to maintain ORP value between 600-900 mV
- Facility conducts required tests at appropriate intervals, as required
- Fail to manually test TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa) 30 minutes prior to opening
- Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)