Wabasca Water World - Swimming Pool
870 Mistassiniy Road S Wabasca AB T0G 2K0 · Aquatic Facility
21 inspections
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.**Update (February 24, 2026): Anti-entrapment plans have still not been updated. Automated Aquatics Canada Ltd. has been tasked to assist with updating the anti-entrapment plans for this facility. PHI has been in contact with Automated Aquatics and received confirmation that they will be coming to assess the facility on March 3/4.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Risk Management Inspection
2 infractions
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- A small yellow slide on the pool deck was observed to have a crack on the bottom of the slide with rough edges in the crevice. Please ensure this crack is filled to prevent physical injury when in use (ie. skin pinch point)**Update (July 31, 2025): the slide has been moved to the side of the pool deck and is not in use so repairs can be completed to seal off the crack.**Update (September 24, 2025): Operator indicated the crack in the slide is still being repaired by facility maintenance. The slide was not observed in the facility at the time of the inspection.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- Risk Management Inspection
2 infractions
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- A small yellow slide on the pool deck was observed to have a crack on the bottom of the slide with rough edges in the crevice. Please ensure this crack is filled to prevent physical injury when in use (ie. skin pinch point)**Update (July 31, 2025): the slide has been moved to the side of the pool deck and is not in use so repairs can be completed to seal off the crack.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The whirlpool suction outlet covers were stated to expire on November 6, 2024 on the anti-entrapment plans and operator confirmed it has not been changed.The outlet covers were observed to be in good repair and free of cracks at the time of inspection.Replace the suction outlet covers and update the anti-entrapment plans.Provide PHI with specifications of the obtained suction outlet covers.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- Risk Management Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Staff indicated that they have been having issues with their blue box system (chemical auto feeder) and are unable to lower/maintain the chlorine levels of the pool. It is also important to note that the Inspector's chemical parameter readings via manual water testing do not match the reading on the automated controller. Investigate the issue and ensure that the blue box system is serviced for the safe operation of the pool. Chemical parameters measured by manual water testing are required to match the readings of the automated controller. If the difference between the two tests is significant, the automated controller probes will need to be cleaned/calibrated. **Note: Facility has contacted Automated Aquatics Canada Ltd. to service the system, which is anticipated to occur on July 23, 2025.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- A small yellow slide on the pool deck was observed to have a crack on the bottom of the slide with rough edges in the crevice. Please ensure this crack is filled to prevent physical injury when in use (ie. skin pinch point)
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- The battery for the digital flow meter is stating 'BATTERY END' and requires changing. Please ensure the battery is replaced to ensure that the flow rate can be adequately monitored.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Pool operating records are not being adequately maintained. The facility's Swimming Pool Manual Water Testing Record Book was observed to be incomplete. The following parameter test records were missing:1. Total Combined Chlorine 2. Water Temperature3. Automated Controller ReadingsPlease ensure that testing records are properly maintained and completed in full as per legislative requirements for safe operation of the aquatic facility.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Staff indicated that they have been having issues with their blue box system (chemical auto feeder) and are unable to lower/maintain the chlorine levels of the pool. It is also important to note that the Inspector's chemical parameter readings via manual water testing do not match the reading on the automated controller. Investigate the issue and ensure that the blue box system is serviced for the safe operation of the pool. Chemical parameters measured by manual water testing are required to match the readings of the automated controller. If the difference between the two tests is significant, the automated controller probes will need to be cleaned/calibrated. **Note: Facility has contacted Automated Aquatics Canada Ltd. to service the system, which is anticipated to occur on July 23, 2025.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- A small yellow slide on the pool deck was observed to have a crack on the bottom of the slide with rough edges in the crevice. Please ensure this crack is filled to prevent physical injury when in use (ie. skin pinch point)
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- The battery for the digital flow meter is stating 'BATTERY END' and requires changing. Please ensure the battery is replaced to ensure that the flow rate can be adequately monitored.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Pool operating records are not being adequately maintained. The facility's Swimming Pool Manual Water Testing Record Book was observed to be incomplete. The following parameter test records were missing:1. Total Combined Chlorine 2. Water Temperature3. Automated Controller ReadingsPlease ensure that testing records are properly maintained and completed in full as per legislative requirements for safe operation of the aquatic facility.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Unsatisfactory water sample result received. Sample submitted on April 16, 2025.Total Coliforms = PRESENT
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological test result showed presence of Total Coliform in the water sample.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample submitted for bacteriological testing was not processed due to incorrect information provided by the collector.Ensure that correct information is provided with proper sampling method. Ensure that water samples are submitted weekly for bacteriological testing.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological test result showed presence of Total Coliform in the water sample.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological test result showed presence of Total Coliform in the water sample.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological test result showed presence of Total Coliform in the water sample.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water samples for microbiological testing have not been submitted since November 15, 2023. Ensure that weekly samples are submitted to the provincial lab for analysis.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Bacteriological test result showed presence of Total Coliform in the water sample. Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Pool volume: 144000 gallonsFlow rate: 376 gpmTurnover rate: 6.38 hours (unsatisfactory)Unsatisfactory turnover was noted with insufficient flow rate. Ensure that there is adequate flow to allow complete recirculation of the pool water within 6 hours.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?