Wabasca Water World - Whirlpool

870 Mistassiniy Road S Wabasca AB T0G 2K0 · Aquatic Facility

50 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    0 infractions

  3. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample result received.Submitted on June 24, 2026.Total Coliforms: PRESENT
  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Unsatisfactory water sample received with a HPC of 260.Whirlpool is being drained and cleaned. Operator will resample once chemical parameters are rebalanced.
  5. Risk Management Inspection

    0 infractions

  6. Risk Management Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.**Update (February 24, 2026): Anti-entrapment plans have still not been updated. Automated Aquatics Canada Ltd. has been tasked to assist with updating the anti-entrapment plans for this facility. PHI has been in contact with Automated Aquatics and received confirmation that they will be coming to assess the facility on March 3/4.
  7. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample taken April 15 indicated presence of Pseudomonas.Pseudomonas: IsolatedOperator agreed to close, shock chlorinate and resample. Facility can reopen once a negative pseudomonas result is received.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample taken April 15 showed presence of HPC.HPC: 980Operator agreed to close, shock chlorinate and resample. Facility can re-open once an acceptable result is received.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.**Update (February 24, 2026): Anti-entrapment plans have still not been updated. Automated Aquatics Canada Ltd. has been tasked to assist with updating the anti-entrapment plans for this facility. PHI has been in contact with Automated Aquatics and received confirmation that they will be coming to assess the facility on March 3/4.
  8. Risk Management Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.**Update (February 24, 2026): Anti-entrapment plans have still not been updated. Automated Aquatics Canada Ltd. has been tasked to assist with updating the anti-entrapment plans for this facility. PHI has been in contact with Automated Aquatics and received confirmation that they will be coming to assess the facility on March 3/4.
  9. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample result received.Submitted on March 11, 2026.Pseudomonas aeruginosa: ISOLATED
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample result received.Submitted on March 11, 2026.Total Coliforms: PRESENT
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Unsatisfactory water sample result received.Submitted on March 11, 2026.HPC: 1,900 CFU/mL
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.**Update (February 24, 2026): Anti-entrapment plans have still not been updated. Automated Aquatics Canada Ltd. has been tasked to assist with updating the anti-entrapment plans for this facility. PHI has been in contact with Automated Aquatics and received confirmation that they will be coming to assess the facility on March 3/4.
  10. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample result received.Submitted on March 11, 2026.Total Coliforms: PRESENT
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.**Update (February 24, 2026): Anti-entrapment plans have still not been updated. Automated Aquatics Canada Ltd. has been tasked to assist with updating the anti-entrapment plans for this facility. PHI has been in contact with Automated Aquatics and received confirmation that they will be coming to assess the facility on March 3/4.
  11. Monitoring Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.**Update (February 24, 2026): Anti-entrapment plans have still not been updated. Automated Aquatics Canada Ltd. has been tasked to assist with updating the anti-entrapment plans for this facility. PHI has been in contact with Automated Aquatics and received confirmation that they will be coming to assess the facility on March 3/4.
  12. Risk Management Inspection

    2 infractions

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The flow meter was observed to be not functioning properly to determine adequate flow on water for the whirlpool basin. Please ensure the flow meter is repaired accordingly.**Note: Operator has contacted Automated Aquatics Ltd. to service/replace the flow meter, which is anticipated to occur on July 23, 2025.**Update (July 31, 2025): The flow meter was still observed to be in disrepair (water damaged screen). Operator indicated that Automated Aquatics Ltd. needs to order a replacement part for the flow meter, which is anticipated to be completed by the end of August 2025.**Update (September 24, 2025): Operator and facility maintenance indicated that the flow meter is still under repair.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans have not been updated to reflect the new installation of suction outlet covers. Ensure the anti-entrapment plans are updated and submitted to Public Health Inspector for review/verification.
  13. Risk Management Inspection

    2 infractions

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The flow meter was observed to be not functioning properly to determine adequate flow on water for the whirlpool basin. Please ensure the flow meter is repaired accordingly.**Note: Operator has contacted Automated Aquatics Ltd. to service/replace the flow meter, which is anticipated to occur on July 23, 2025.**Update (July 31, 2025): The flow meter was still observed to be in disrepair (water damaged screen). Operator indicated that Automated Aquatics Ltd. needs to order a replacement part for the flow meter, which is anticipated to be completed by the end of August 2025.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The main pool suction outlet covers were stated to expire on November 8, 2024 on the anti-entrapment plans and operator confirmed it has not been changed.The outlet covers were observed to be in good repair and free of cracks at the time of inspection.Replace the suction outlet covers and update the anti-entrapment plans.Provide PHI with specifications of the obtained suction outlet covers.
  14. Risk Management Inspection

    4 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FAC residual of the whirlpool was measured at 1.03 ppm (mg/L) via manual water testing. The automated controller reading was measured at 2.21 ppm (mg/L). With the malfunctioning automated controller, the reading measured may not be accurate.**Update (July 31, 2025): FAC residual via manual water testing is still below the minimum required concentration of 2.0 ppm (mg/L). Manual water test results measured a FAC residual of 1.71 ppm (mg/L). PHI advised staff to increase the FAC for the whirlpool. Ensure that the FAC residual of the whirlpool is maintained at no less than 2.0 ppm (mg/L) for adequate disinfection.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Staff indicated that they have been having issues with their blue box system (chemical auto feeder) and are unable to lower/maintain the chlorine levels of the pool. It is also important to note that the Inspector's chemical parameter readings via manual water testing do not match the reading on the automated controller. Investigate the issue and ensure that the blue box system is serviced for the safe operation of the pool. Chemical parameters measured by manual water testing are required to match the readings of the automated controller. If the difference between the two tests is significant, the automated controller probes will need to be cleaned/calibrated. **Note: Facility has contacted Automated Aquatics Canada Ltd. to service the system, which is anticipated to occur on July 23, 2025.**Update (July 31, 2025): The required servicing has been completed for the blue box system, however, the automated controller readings are still not matching the readings obtained via manual water testing. PHI advised staff to re-calibrate the probes on the automatic controller and to complete manual water tests after the calibration is completed for comparison. Chemical parameters measured by manual water testing must be consistent with the readings of the automated controller.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The flow meter was observed to be not functioning properly to determine adequate flow on water for the whirlpool basin. Please ensure the flow meter is repaired accordingly.**Note: Operator has contacted Automated Aquatics Ltd. to service/replace the flow meter, which is anticipated to occur on July 23, 2025.**Update (July 31, 2025): The flow meter was still observed to be in disrepair (water damaged screen). Operator indicated that Automated Aquatics Ltd. needs to order a replacement part for the flow meter, which is anticipated to be completed by the end of August 2025.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The main pool suction outlet covers were stated to expire on November 8, 2024 on the anti-entrapment plans and operator confirmed it has not been changed.The outlet covers were observed to be in good repair and free of cracks at the time of inspection.Replace the suction outlet covers and update the anti-entrapment plans.Provide PHI with specifications of the obtained suction outlet covers.
  15. Risk Management Inspection

    5 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FAC residual of the whirlpool was measured at 1.03 ppm (mg/L) via manual water testing. The automated controller reading was measured at 2.21 ppm (mg/L). With the malfunctioning automated controller, the reading measured may not be accurate.Ensure that the FAC residual of the whirlpool is maintained at no less than 2.0 ppm (mg/L) for adequate disinfection.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Staff indicated that they have been having issues with their blue box system (chemical auto feeder) and are unable to lower/maintain the chlorine levels of the pool. It is also important to note that the Inspector's chemical parameter readings via manual water testing do not match the reading on the automated controller. Investigate the issue and ensure that the blue box system is serviced for the safe operation of the pool. Chemical parameters measured by manual water testing are required to match the readings of the automated controller. If the difference between the two tests is significant, the automated controller probes will need to be cleaned/calibrated. **Note: Facility has contacted Automated Aquatics Canada Ltd. to service the system, which is anticipated to occur on July 23, 2025.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The flow meter was observed to be not functioning properly to determine adequate flow on water for the whirlpool basin. Please ensure the flow meter is repaired accordingly.**Note: Operator has contacted Automated Aquatics Ltd. to service/replace the flow meter, which is anticipated to occur on July 23, 2025.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Sand was observed in the whirlpool basin. Investigate the cause of sand debris accumulation in the pool and ensure that the debris is cleaned out to ensure satisfactory water quality.**Note: Operator has contacted Automated Aquatics Ltd. to come in and investigate the issue, which is anticipated to occur on July 25, 2025.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Pool operating records are not being adequately maintained. The facility's Swimming Pool Manual Water Testing Record Book was observed to be incomplete. The following parameter test records were missing:1. Total Combined Chlorine 2. Water Temperature3. Automated Controller ReadingsPlease ensure that testing records are properly maintained and completed in full as per legislative requirements for safe operation of the aquatic facility.
  16. Risk Management Inspection

    0 infractions

  17. Monitoring Inspection

    5 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FAC residual of the whirlpool was measured at 1.03 ppm (mg/L) via manual water testing. The automated controller reading was measured at 2.21 ppm (mg/L). With the malfunctioning automated controller, the reading measured may not be accurate.Ensure that the FAC residual of the whirlpool is maintained at no less than 2.0 ppm (mg/L) for adequate disinfection.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Staff indicated that they have been having issues with their blue box system (chemical auto feeder) and are unable to lower/maintain the chlorine levels of the pool. It is also important to note that the Inspector's chemical parameter readings via manual water testing do not match the reading on the automated controller. Investigate the issue and ensure that the blue box system is serviced for the safe operation of the pool. Chemical parameters measured by manual water testing are required to match the readings of the automated controller. If the difference between the two tests is significant, the automated controller probes will need to be cleaned/calibrated. **Note: Facility has contacted Automated Aquatics Canada Ltd. to service the system, which is anticipated to occur on July 23, 2025.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • The flow meter was observed to be not functioning properly to determine adequate flow on water for the whirlpool basin. Please ensure the flow meter is repaired accordingly.**Note: Operator has contacted Automated Aquatics Ltd. to service/replace the flow meter, which is anticipated to occur on July 23, 2025.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Sand was observed in the whirlpool basin. Investigate the cause of sand debris accumulation in the pool and ensure that the debris is cleaned out to ensure satisfactory water quality.**Note: Operator has contacted Automated Aquatics Ltd. to come in and investigate the issue, which is anticipated to occur on July 25, 2025.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Pool operating records are not being adequately maintained. The facility's Swimming Pool Manual Water Testing Record Book was observed to be incomplete. The following parameter test records were missing:1. Total Combined Chlorine 2. Water Temperature3. Automated Controller ReadingsPlease ensure that testing records are properly maintained and completed in full as per legislative requirements for safe operation of the aquatic facility.
  18. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample result received.Submitted on June 25, 2025. Total Coliforms: PRESENT
  19. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample result received.Submitted on November 13, 2024Total Coliforms: PRESENT
  20. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample result received.Submitted on October 2, 2024Total Coliforms: PRESENTNote: Operator confirmed that hot tub was drained, cleaned and sanitized as of Thursday Oct. 3rd, 2024
  21. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Unsatisfactory water sample result received.Submitted on September 25, 2024Total Coliforms: PRESENTEnsure that a re-sample is done as soon as possible
  22. Risk Management Inspection

    0 infractions

  23. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample from August 7, has Total Coliforms present. Discussed the results with the operator. Operator advised that the pool was drained and scrubbed last week due to water sample results last week being present for Total Coliforms and Pseudomonas.Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance the water chemistry and resample.
  24. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total Coliforms and Pseudomonas aeruginosa have been identified in water sample submitted on July 31, 2024. Please ensure pool is drained and treated in accordance with AHS Guidance as per: https://www.albertahealthservices.ca/assets/wf/eph/wf-eh-pseudomona-in-hot-tubs.pdf.
  25. Risk Management Inspection

    0 infractions

  26. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total Coliforms present from water sample collected on June 26, 2024.Please ensure water sample is submitted as soon as possible.
  27. Risk Management Inspection

    0 infractions

  28. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow meter is not functioning properly to determine adequate flow for the whirlpool basin. Please ensure the flow meter is repaired accordingly.
  29. Monitoring Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The bacteriological water test result showed presence for total coliforms. Pseudomonas was ABSENT.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flow meter is not functioning properly to determine adequate flow for the whirlpool basin. Please ensure the flow meter is repaired accordingly.
  30. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The bacteriological water test result showed presence for total coliforms. Pseudomonas was ABSENT.
  31. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The bacteriological water test result showed presence of Pseudomonas aeruginosa. The operator stated that the whirlpool will be out of service until corrective actions are made. The whirlpool will be drained, cleaned, and disinfected on June 3rd, 2024. Pseudomonas aeruginosa Information Sheet was provided to the operator by email.
  32. Risk Management Inspection

    0 infractions

  33. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flowmeter for the filtration system of the whirlpool basin was noted to be in disrepair. Ensure that a flow rate monitoring system is in working order to ensure adequate filtration and turnover of the pool water.Update (March 26, 2024): While visual signs of water flow were noted, the flowmeter remains in disrepair. Flow rate and turnover is unknown.
  34. Risk Management Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample submitted for bacteriological testing was not processed due to incorrect information provided by the collector.Ensure that correct information is provided with proper sampling method. Ensure that water samples are submitted weekly for bacteriological testing.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flowmeter for the filtration system of the whirlpool basin was noted to be in disrepair. Ensure that a flow rate monitoring system is in working order to ensure adequate filtration and turnover of the pool water.Update (March 26, 2024): While visual signs of water flow were noted, the flowmeter remains in disrepair. Flow rate and turnover is unknown.
  35. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flowmeter for the filtration system of the whirlpool basin was noted to be in disrepair. Ensure that a flow rate monitoring system is in working order to ensure adequate filtration and turnover of the pool water.Update (March 26, 2024): While visual signs of water flow were noted, the flowmeter remains in disrepair. Flow rate and turnover is unknown.
  36. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flowmeter for the filtration system of the whirlpool basin was noted to be in disrepair. Ensure that a flow rate monitoring system is in working order to ensure adequate filtration and turnover of the pool water.Update (march 19, 2024): The hot tub was noted to be drained empty due to damage in the tiles on the interior wall of the pool. Flow rate was not observable.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • A large piece of the inside wall tile of the hot tub was noted to have fallen out. The pool has been drained and closed until repair work is complete.
  37. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The flowmeter for the filtration system of the whirlpool basin was noted to be in disrepair. Ensure that a flow rate monitoring system is in working order to ensure adequate filtration and turnover of the pool water.
  38. Risk Management Inspection

    0 infractions

  39. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Total Coliform in the water sample.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.Update (January 30, 2024): Second sample test shows unsatisfactory result with Total Coliforms present. Whirlpool basin is voluntarily closed by the operator.
  40. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Total Coliform in the water sample.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.Update (January 30, 2024): Second sample test shows unsatisfactory result with Total Coliforms present. Whirlpool basin is voluntarily closed by the operator.
  41. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Total Coliform in the water sample.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
  42. Risk Management Inspection

    0 infractions

  43. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated chemical monitoring device remains in disrepair.
  44. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water samples for microbiological testing have not been submitted since November 15, 2023. Ensure that weekly samples are submitted to the provincial lab for analysis.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated chemical monitoring device remains in disrepair with readings indicating free available chlorine level at 0.99 ppm, and pH at 7.61.
  45. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated chemical monitoring device remains in disrepair with readings indicating free available chlorine level at 0.99 ppm, and pH at 7.61.
  46. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Total Coliform in the water sample collected.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Pseudomonas aeruginosa.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Temperature: 39.6 degrees CelsiusFree Available Chlorine: 1.38 ppmpH: 6.5Both pH and FAC tests show unsatisfactory results, below the minimum requirement.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated chemical monitoring device was noted to be in disrepair.
  47. Risk Management Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Temperature: 39.6 degrees CelsiusFree Available Chlorine: 1.38 ppmpH: 6.5Both pH and FAC tests show unsatisfactory results, below the minimum requirement.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated chemical monitoring device was noted to be in disrepair.
  48. Risk Management Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Total Coliform in the water sample collected on the day of inspection.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Pseudomonas aeruginosa.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Pool volume: 3800 gallonsFlow rate: UnknownTurnover rate: UnknownFlowmeter for the filtration system of the whirlpool basin was noted to be in disrepair. Ensure that a flow rate monitoring system is in working order to ensure adequate filtration and turnover of the pool water.
  49. Risk Management Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Total Coliform in the water sample collected on the day of inspection.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Pseudomonas aeruginosa.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free Chlorine: 1.67 ppmpH: 7.9Temperature: 39.7degrees CelsiusFree available chlorine concentration was noted to be below the minimum requirement of 2.0 ppm in a pool above 30 degrees Celsius. The pH of the water in the pool was also unsatisfactory with pH measured above the maximum accepted level of 7.6. Ensure that all chemical parameters are maintained within the acceptable ranges to ensure adequate disinfection of the pool water.Update: Repair work has not been completed. Whirlpool basin remains closed.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Pool volume: 3800 gallonsFlow rate: UnknownTurnover rate: UnknownFlowmeter for the filtration system of the whirlpool basin was noted to be in disrepair. Ensure that a flow rate monitoring system is in working order to ensure adequate filtration and turnover of the pool water.
  50. Monitoring Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological test result showed presence of Total Coliform in the water sample collected on the day of inspection.Steps to respond to unsatisfactory bacteriological sample results were provided to the operator by email. Please ensure that corrective actions are completed to adequately disinfect the pool, and that samples are collected appropriately to prevent sampling error.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free Chlorine: 1.67 ppmpH: 7.9Temperature: 39.7degrees CelsiusFree available chlorine concentration was noted to be below the minimum requirement of 2.0 ppm in a pool above 30 degrees Celsius. The pH of the water in the pool was also unsatisfactory with pH measured above the maximum accepted level of 7.6. Ensure that all chemical parameters are maintained within the acceptable ranges to ensure adequate disinfection of the pool water.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Pool volume: 3800 gallonsFlow rate: UnknownTurnover rate: UnknownFlowmeter for the filtration system of the whirlpool basin was noted to be in disrepair. Ensure that a flow rate monitoring system is in working order to ensure adequate filtration and turnover of the pool water.