Skip to content
Loading map…

Woodlands Water Play Park - Splash Pad

165 Sturgeon Road St. Albert AB T8N 3G1 · Aquatic Facility

Inspection summary

Woodlands Water Play Park - Splash Pad has been inspected 7 times by Alberta Health Services (Environmental Public Health) since May 16, 2024. The most recent inspection, on August 28, 2026, found no infractions.

4 of 7 inspections on record found no infractions at all. In the past 12 months there were 3 inspections with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 3 times across 3 separate inspections, most recently on August 20, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

7 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was noted above 57000 CFU/mL.
  3. Monitoring Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC: count was noted to be at 970 CFU/mL.The operator was advised to increase the free chlorine levels.
  5. Monitoring Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was calculated at 510 CFU/mL.The operator was advised to increase the free chlorine levels.
  7. Monitoring Inspection

    0 infractions

Nearby inspected facilities