Inspection summary

Wynn Nails & Spa has been inspected 6 times by Alberta Health Services (Environmental Public Health) since March 12, 2025. The most recent inspection, on September 11, 2026, found no infractions.

1 of 6 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 4 infractions recorded. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.

Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 11 times across 5 separate inspections, most recently on September 10, 2026. For example: Is reusable equipment disinfected properly?

  • Food safety training and certificationLower risk

    Some jurisdictions require operators to complete infection-prevention training, or to hold specific qualifications for higher-risk services such as tattooing, piercing or electrolysis. These findings mean the training record was missing at the time. They do not by themselves mean a client was put at risk.

    Recorded 2 times across 2 separate inspections, most recently on July 9, 2025. For example: Do operators and personal services workers comply with the Personal Services Regulation and Standards and do they have the skills and knowledge to perform their duties in a safe and sanitary manner?

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded 2 times on September 10, 2026. For example: Are waste sharps disposed of properly?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

6 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    4 infractions

    • 20. Is reusable equipment disinfected properly?
      • 1. PREempt CS20 used for disinfecting semi-critical equipment was expired.2. PREempt RTU used for disinfecting chairs, tables, pedicure foot baths, and other non-critical surfaces was expired.3. Test strips to test PREempt CS 20 were expired.4. High-level disinfectant testing records for reusing PREempt CS20 were incomplete.5. Semi-critical tools were not fully submerged in the PREempt CS20 solution during the disinfection process.Corrective Actions:1. Obtain and use new PREempt CS20, PREempt RTU, and test strips. Regularly check expiry dates to ensure products are not used beyond their expiry date.2. If reusing PREempt CS20, test daily using test strips and record the results.3. Ensure semi-critical tools are fully submerged in PREempt CS20 for the required 20-minute contact time during disinfection.
    • 24. Are waste sharps disposed of properly?
      • A proper puncture-resistant sharps container was not available. Used sharps were being stored in a plastic container.- Use an approved puncture-resistant sharps container with a tight-fitting lid and ensure all sharps are immediately discarded into the container after use.
    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • Wooden applicator sticks were observed being double dipped into wax pots. Double dipping can contaminate the wax with microorganisms and increase the risk of infection transmission between clients.Actions Taken:- The wax pot was discarded during the inspection, and staff were educated not to double dip applicators into wax products.- Ensure a new applicator stick is used each time product is removed from the wax pot to prevent contamination of the bulk supply.
    • 27. Is the facility maintained in a visibly clean state and are environmental surfaces cleaned and disinfected properly?
      • Sept 10, 2025: The violation noted below remains outstanding- dust was observed on manicure stations and wax tables.October 14, 2025: An accumulation of nail dust was observed on surfaces in the manicure stations, a build-up lotion observed on the handle of the towel warmer, dust observed in the washroom area. - Clean and maintain in a clean and sanitary condition at all times.- All client contact surfaces must be disinfected after each client using a low-level disinfected such as Lysol wipes. July 10, 2025: Some cleaning had been done. More required. July 9, 2025: Unsanitary conditions found throughout the facility including but not limited to: an accumulation of nail dust on surfaces in the manicure stations, dirty paraffin and cleanser containers, dirty floors and walls. - Clean and maintain in a clean and sanitary condition at all times.
  3. Demand Inspection

    1 infraction

    • 27. Is the facility maintained in a visibly clean state and are environmental surfaces cleaned and disinfected properly?
      • October 14, 2025: An accumulation of nail dust was observed on surfaces in the manicure stations, a build-up lotion observed on the handle of the towel warmer, dust observed in the washroom area. - Clean and maintain in a clean and sanitary condition at all times.- All client contact surfaces must be disinfected after each client using a low-level disinfected such as Lysol wipes. July 10, 2025: Some cleaning had been done. More required. July 9, 2025: Unsanitary conditions found throughout the facility including but not limited to: an accumulation of nail dust on surfaces in the manicure stations, dirty paraffin and cleanser containers, dirty floors and walls. - Clean and maintain in a clean and sanitary condition at all times.
  4. Risk Management Inspection

    1 infraction

    • 27. Is the facility maintained in a visibly clean state and are environmental surfaces cleaned and disinfected properly?
      • July 10, 2025: Some cleaning had been done. More required. July 9, 2025: Unsanitary conditions found throughout the facility including but not limited to: an accumulation of nail dust on surfaces in the manicure stations, dirty paraffin and cleanser containers, dirty floors and walls. - Clean and maintain in a clean and sanitary condition at all times.
  5. Demand Inspection

    5 infractions

    • 06. Do operators and personal services workers comply with the Personal Services Regulation and Standards and do they have the skills and knowledge to perform their duties in a safe and sanitary manner?
      • Written protocols for disinfection on the wall in the back room near the sink were blank and not being followed. Complete a step-by-step instruction for cleaning and disinfecting tools and pedicure tub and train all personal service workers and provide confirmation of training.
    • 13. Is single-use or uncleanable equipment being used as intended (Critical)?
      • Used nail files, sanding bands are stored in the manicure table drawers and storage. Ensure single-use items such as nail files, sanding bands that cannot be cleaned properly are discarded after use.
    • 17. Is reusable equipment cleaned properly (Critical)?
      • Inadequate cleaning of tools and equipment prior to submerging into disinfectant evident by presence of several nail in the disinfectant solution. - All reusable equipment and tools must be washed with detergent and rinse with water. Next dry the tools prior to soaking into the disinfectant solution.
    • 20. Is reusable equipment disinfected properly?
      • 1) The concentration of CS20 in disinfection container was measured at 0%. 2) Testing records required to assess the efficacy of the high-level disinfectant Preempt CS20, were not maintained. The CS20 log was blank. 3) The CS20 concentration is not being tested daily. - The solution must be discarded daily or discarded after 14 days or sooner as dictated by AHP7 Test Strips.3) An intermediate disinfectant was not available for disinfection of pedicure basins. - Ensure pedicure tubs are cleaned with soap and water, dried, sprayed with an intermediate-level disinfectant such as RTU for an adequate amount of time as required by manufacturer, rinsed, and dried.4) Contact time required for Preempt CS20, is not being achieved. Operator indicated tools are submerged in the solution for up to 15 minutes before removing.- Follow the manufacturer's instructions. A 20-minute contact time is required.
    • 27. Is the facility maintained in a visibly clean state and are environmental surfaces cleaned and disinfected properly?
      • 1) Unsanitary conditions found throughout the facility including but not limited to: an accumulation of nail dust on surfaces in the manicure stations, dirty paraffin and cleanser containers, dirty floors and walls. - Clean and maintain in a clean and sanitary condition at all times.
  6. Demand Inspection

    4 infractions

    • 06. Do operators and personal services workers comply with the Personal Services Regulation and Standards and do they have the skills and knowledge to perform their duties in a safe and sanitary manner?
      • Facility has some written protocols for client care on the wall in the back room near the sink. However, they are water damaged and not being accurately followed. Please complete a step-by-step instruction for cleaning and disinfecting tools and pedicure tub and train all personal service workers on them.
    • 13. Is single-use or uncleanable equipment being used as intended (Critical)?
      • Used nail files, sanding bands are stored in the manicure table drawers and storage. Ensure single-use items such as nail files, sanding bands that cannot be cleaned properly are discarded after use.
    • 20. Is reusable equipment disinfected properly?
      • 1) Pedicure and manicure re-usable equipment are not disinfected adequately. CS20 and RTU disinfectants that were in use were both expired.- Operators were able obtain disinfectant while PHI was on-site. - A high-level disinfectant such as PREempt CS20 is required for semi-critical tools such as pedicure and manicure instruments. Follow the manufacturer's instructions. Equipment must be cleaned with detergent and hot water, then rinsed with hot water, dried, prior to submersion in the CS20 for minimum of 20 minutes. CS20 solution must decarded daily.2) Pedicure tubs are washed and rinsed only and not disinfected. RTU was expired. - Operators were able obtain disinfectant while PHI was on-site.An intermediate-level disinfectant such as PREempt RTU. Follow the manufacturer's instructions. Tubs must be cleaned with detergent and hot water, then rinsed with hot water, dried, prior to applying the RTU for 3 minutes.
    • 27. Is the facility maintained in a visibly clean state and are environmental surfaces cleaned and disinfected properly?
      • 1) Unsanitary conditions found throughout the facility including but not limited to: an accumulation of nail dust on surfaces in the manicure stations, dirty paraffin and cleanser containers, dirty floors and walls. - Clean and maintain in a clean and sanitary condition at all times.