Skip to content
Loading map…

YMCA Main Spa - Indoor Pool

235 McNabb Street Sault Ste. Marie ON P6B 1Y3 · Indoor Pool

11 inspections

  1. Required

    2 infractions

    • Daily spa tests and records completed
      • The reading of the make-up water meter must be recorded (applicable to spas with a total volume in excess of 4000 litres) [Sec. 8(b)]
      • Tests for total alkalinity, pH value, free available chlorine and total chlorine or bromine residual, water clarity, and water temperature are taken and recorded regarding the spa water each operating day, a minimum of 30 minutes prior to opening [Sec. 7(11)]
      • The land line emergency telephone is tested to confirm that it is in operating condition and is directly connected to an emergency service or local telephone utility before the spa is opened for use each day [Sec. 8(g)]
    • Weekly and monthly tests and records completed
      • The test-buttons associated with the ground current leakage detecting and de-energizing devices are activated during the daily use period and must be tested either monthly, or according to the manufacturer’s instructions, whichever is more frequent [Sec. 16.1(c)]
      • The vacuum release mechanism must be tested and inspected at least once within each period of 30 operating days [Sec. 16.1(f)]
  2. Required

    3 infractions

    • Daily spa tests and records completed
      • The time at which each spa test is completed is to be recorded [Sec. 8]
      • Estimated number of bather uses during the operating day must be recorded [Sec. 8(a)]
      • The reading of the make-up water meter must be recorded (applicable to spas with a total volume in excess of 4000 litres) [Sec. 8(b)]
      • For a spa with an automatic sensing device, total alkalinity, pH value, free available chlorine and total chlorine or bromine residual, water clarity, and water temperature checked and recorded every four hours until the daily use period has ended [Sec. 7(12)]
      • The date the spa was drained and the findings of the empty spa inspection must be documented [Sec. 8(f)]
      • The land line emergency telephone is tested to confirm that it is in operating condition and is directly connected to an emergency service or local telephone utility before the spa is opened for use each day [Sec. 8(g)]
    • Weekly and monthly tests and records completed
      • Water, gravity, and suction outlet covers must be inspected at least once within each period of 30 operating days [Sec. 16.1(a)]
      • The test-buttons associated with the ground current leakage detecting and de-energizing devices are activated during the daily use period and must be tested either monthly, or according to the manufacturer’s instructions, whichever is more frequent [Sec. 16.1(c)]
      • Emergency stop button must be tested and inspected at least once within each period of 30 operating days [Sec. 16.1(f)]
      • The vacuum release mechanism must be tested and inspected at least once within each period of 30 operating days [Sec. 16.1(f)]
    • Free available chlorine (FAC) levels adequately maintained between 5 ppm – 10 ppm [Sec. 7(8)(c)]
      • The FAC level must be adjusted to the range of 5 ppm – 10 ppm in every part of the spa [Sec. 7(8)(c)]
  3. Required

    0 infractions

  4. Required

    1 infraction

    • Free available chlorine (FAC) levels adequately maintained between 5 ppm – 10 ppm [Sec. 7(8)(c)]
      • The FAC level must be adjusted to the range of 5 ppm – 10 ppm in every part of the spa [Sec. 7(8)(c)]
  5. Required

    0 infractions

  6. Required

    0 infractions

  7. Follow-up

    0 infractions

  8. Required

    3 infractions

    • Weekly and monthly tests and records completed
      • Emergency stop button must be tested and inspected at least once within each period of 30 operating days [Sec. 16.1(f)]
    • An emergency stop button is accessible in the event of emergency [Sec. 26]
      • An emergency stop button must be provided and capable of deactivating all pumps used in the operation of the spa [Sec. 26(1)]
      • The emergency stop button must be located within the vicinity of the spa and activate an audible and visual signal when used [Sec. 26(1)(b-c)]
    • Free available chlorine (FAC) levels adequately maintained between 5 ppm – 10 ppm [Sec. 7(8)(c)]
      • The FAC level must be adjusted to the range of 5 ppm – 10 ppm in every part of the spa [Sec. 7(8)(c)]
  9. Follow-up

    0 infractions

  10. Required

    0 infractions

  11. Required

    0 infractions