AL RABY HIGH SCHOOL
3545 W Fulton, CHICAGO, IL 60624 · School
19 inspections
- Canvass
2 infractions
- 49. NON-FOOD/FOOD CONTACT SURFACES CLEAN
- MUST CLEAN AND MAINTAIN STORAGE SHELVING TO REMOVE DEBRIS.
- 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
- FLOORS IN THE PREP AREA ALONG THE WALL BASE AND IN CORNERS NEED CLEANING TO REMOVE DEBRIS AND/OR SPILLS.
- 49. NON-FOOD/FOOD CONTACT SURFACES CLEAN
- Canvass
3 infractions
- 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
- OBSERVED HANDWASHING SIGNAGE INFORMING PERSONS TO WASH HANDS MISSING FROM THE FOLLOWING HANDWASHING SINKS: 3RD FLOOR BOYS RESTROOM, 2ND FLOOR BOYS RESTROOM. INSTRUCTED TO PROVIDE ADEQUATE HANDWASHING SIGNAGE TO ALL HANDWASHING SINKS AND MAINTAIN AT ALL TIMES.
- 51. PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
- OBSERVED LEAK IN WALL PLUMBING FOR MAIN KITCHEN AREA 3-COMPARTMENT SINK WHILE WATER SUPPLY RUNNING. SCHOOL ENGINEER AWARE OF ISSUE PRIOR TO INSPECTION AND PROVIDED PROOF OF PENDING SERVICE REQUEST FOR REPAIRS. KITCHEN HAS THREE ADDITIONAL 3-COMPARTMENT SINKS ON ADJACENT WALL EQUIPPED FOR WAREWASHING WITH ADEQUATE HOT AND COLD WATER. INSTRUCTED TO REPAIR/REPLACE KITCHEN AREA 3-COMPARTMENT SINK WALL PLUMBING TO ELIMINATE LEAK AND MAINTAIN ALL PLUMBING FIXTURES IN GOOD REPAIR.
- 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
- OBSERVED FLOORS BEHIND EQUIPMENT IN THE MAIN KITCHEN AREA (STOVE/GRILLS/HOT-HOLDING CABINETS) TO BE HEAVILY SOILED WITH DRIED FOOD DEBRIS AND DUST. INSTRUCTED TO CLEAN FLOORS BENEATH AND BEHIND EQUIPMENT AT ADEQUATE FREQUENCY TO PREVENT BUILD UP OF DEBRIS AND OTHER SOILS AND MAINTAIN.
- 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
- Canvass
1 infraction
- 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
- OBSERVED CRACK IN EAST WALL OF DRY STORAGE ROOM OFF KITCHEN AREA. INSTRUCTED PERSON IN CHARGE TO REPAIR AND MAINTAIN SMOOTH AND EASILY CLEANABLE.
- 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
- Canvass
1 infraction
- 53. TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED
- OBSERVED NO COVERED RECEPTACLE IN THE STAFF TOILET ROOM LOCATED ON THE FIRST FLOOR NEAR THE KITCHEN. INSTRUCTED TO PROVIDE AND MAINTAIN.
- 53. TOILET FACILITIES: PROPERLY CONSTRUCTED, SUPPLIED, & CLEANED
- Canvass
0 infraction
- Canvass
2 infractions
- 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
- NO HAND WASHING SINK IN THE REAR DISH WASHING/PREP AREA. INSTRUCTED TO INSTALL AND MAINTAIN. PRIORITY FOUNDATION VIOLATION 7-38-030(c)
- 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
- OBSERVED A ONE DOOR COOLER IN THE SERVING LINE AREA IN DISREPAIR. INSTRUCTED TO REPAIR OR REPLACE AND MAINTAIN
- 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
- Canvass
6 infractions
- 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
- **OBSERVED NO EXPOSED HAND SINK AT THE SERVING LINE. INSTRUCTED MANAGER TO COMPLY WITH THE NEW CODE OR CITATIONS WILL FOLLOW. PRIORITY FOUNDATION VIOLATION #7-38-030(C).
- 16. FOOD-CONTACT SURFACES: CLEANED & SANITIZED
- CULINARY CLASS: MUST CLEAN AND SANITIZE MIXER AND IT'S ATTACHMENTS.
- 36. THERMOMETERS PROVIDED & ACCURATE
- CULINARY CLASS: INSTRUCTED MANAGER TO PROVIDE AND MAINTAIN WORKING THERMOMETERS INSIDE ALL REACH IN COOLERS.
- 49. NON-FOOD/FOOD CONTACT SURFACES CLEAN
- CULINARY CLASS: MUST DETAIL CLEAN THE INTERIOR OF ALL REACH IN COOLERS AND FREEZERS TO REMOVE SPILLS AND DEBRIS. ALSO CLEAN THE TRAYS SMALL DEEP FRYERS ARE KEPT ON TO REMOVE GREASE AND DEBRIS. MAIN KITCHEN: MUST DEFROST AND CLEAN THE WALK IN FREEZER #2 TO REMOVE ICE BUILD UP AND DEBRIS.
- 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
- CULINARY CLASS: FLOORS NEED CLEANING IN THE POT & PANS STORAGE ROOM AND AROUND THE 3 COMPARTMENT SINK. MUST CLEAN TO REMOVE DEBRIS.
- 56. ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED
- CULINARY CLASS: MUST CLEAN THE FILTERS ABOVE THE COOKING EQUIPMENT TO REMOVE GREASE.
- 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
- Canvass
1 infraction
- 33. FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
- DETAIL CLEAN THE MILK COOLER AT THE SERVICE LINE.
- 33. FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
- Suspected Food Poisoning
1 infraction
- 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
- LEAKING FAUCET AT THREE COMPARTMENT BY REAR AREA BY WINDOW, INSTRUCTED TO REPAIR,
- 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
- Canvass
3 infractions
- 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
- MUST REMOVE RUST FROM THE 3 COMPARTMENT SINK,INSTRUCTED TO REMOVE RUST
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- MUST CLEAN FLOOR IN THE JANITORS CLOSET ON THE 2ND FLOOR ACROSS FROM LIBRARY,ALONG WALL BASE AND CORNERS
- 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
- MUST REMOVE CLUTTER FROM THE JANITORS CLOSET ON THE 2ND FLOOR ACROSS FROM LIBRARY TO PREVENT RODENT HARBORAGE
- 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
- Canvass Re-Inspection
3 infractions
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- CLEAN FLOORS UNDER ALL EQUIPMENT, ALONG WALLS AND IN ALL CORNERS, IN ALL SCIENCE AND COMPUTER CLASSROOMS.
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- SEAL ALL OPENINGS AROUND PIPE FITTINGS IN WALLS AND CEILINGS IN ALL AREAS. CLEAN VENTS IN WALK-IN COOLER. CLEAN LIGHT SHEILDS IN BOYS 3RD FLOOR WASHROOM.
- 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
- REPLACE MISSING LIGHT SHIELD IN WALK-IN FREEZER.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- Canvass
7 infractions
- 13. NO EVIDENCE OF RODENT OR INSECT INFESTATION, NO BIRDS, TURTLES OR OTHER ANIMALS
- OBSERVED 40 MICE DROPPINGS INSIDE VENT IN UNUSED DISH ROOM, 50 MICE DROPPINGS INSIDE COMPRESSOR UNIT IN BOTTOM OF CHEST FREEZER, 15 MICE DROPPINGS ON ELECTRICAL OUTLETS BEHIND STOVE AND OVEN IN KITCHEN, 5 MICE DROPPINGS ON OUTLETS IN LUNCHROOM, 4 MICE DROPPINGS ON OUTLETS IN TEACHERS LOUNGE, 10 MICE DROPPINGS INSIDE CLOSET IN BIOLOGY LAB ROOM 421, 40 MICE DROPPINGS INSIDE CABINET UNDER SINK NEAR DESK IN SCIENCE ROOM 411, 5 MICE DROPPINGS ON BOTTOM SHELF IN SCIENCE LAB ROOM 324, 10 MICE DROPPINGS ON FLOOR IN CORNER UNDER WINDOW, MICE DROPPINGS ON FLOOR NEAR FILE CABINET, 25 MICE DROPPINGS IN FLOOR INSIDE CLOSET, 20 MICE DROPPINGS SCATTERED ON DESK, 5 MICE DROPPINGS ON FLOOR AROUND DESK, 2 MICE DROPPINGS ON LEDGE BEHIND DESK, 2 MICE DROPPINGS ON COUNTER IN COMPUTER ROOM 225. INSTRUCTED MANAGER TO CALL AN EXTERMINATOR FOR SERVICE, CLEAN AND SANITIZE ALL AREAS. CRITICAL VIOLATION 7-38-020
- 18. NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS
- FOLLOWING DOORS NOT RODENT PROOFED, ENTRANCE #6 NEAR AUDITORIUM, 1/4" GAP ON BOTTOM LEFT CORNER OF DOOR, ENTRANCE #8 1/4" GAP ON BOTTOM OF DOOR. SEAL ALL OUTER OPENINGS ON DOORS TO PREVENT PEST ENTRY. SERIOUS VIOLATION 7-38-020
- 19. OUTSIDE GARBAGE WASTE GREASE AND STORAGE AREA; CLEAN, RODENT PROOF, ALL CONTAINERS COVERED
- OUTSIDE GARBAGE AREA NOT CLEAN AND MAINTAINED. OBSERVED EXCESSIVE TRASH ON GROUND, DUMPSTERS OVERFLOWING, AND LIDS NOT TIGHT-FITTING. INSTRUCTED MANAGER TO CLEAN OUTSIDE GARBAGE AREA. SERIOUS VIOLATION 7-38-020
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- CLEAN FLOORS UNDER ALL EQUIPMENT, ALONG WALLS AND IN ALL CORNERS, IN ALL SCIENCE AND COMPUTER CLASSROOMS.
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- SEAL ALL OPENINGS AROUND PIPE FITTINGS IN WALLS AND CEILINGS IN ALL AREAS. CLEAN VENTS IN WALK-IN COOLER. CLEAN LIGHT SHEILDS IN BOYS 3RD FLOOR WASHROOM.
- 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
- REPLACE MISSING LIGHT SHIELD IN WALK-IN FREEZER.
- 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
- REMOVE ALL UNUSED EQUIPMENT AND ARTICLES IN CLASSROOM AND STORAGE AREAS TO PREVENT PEST HARBORAGE.
- 13. NO EVIDENCE OF RODENT OR INSECT INFESTATION, NO BIRDS, TURTLES OR OTHER ANIMALS
- Canvass Re-Inspection
4 infractions
- 13. NO EVIDENCE OF RODENT OR INSECT INFESTATION, NO BIRDS, TURTLES OR OTHER ANIMALS
- STILL OBSERVED EVIDENCE OF RODENT INFESTATION THROUGHOUT THE CLASSROOMS AND IN THE KITCHEN DISHROOM AND PREP AREA. OBSERVED 20 MOUSE DROPPINGS ON THE STORAGE BOXES IN THE DISHROOM, OBSERVED 10 MOUSE DROPPINGS ON THE STAINLESS STEEL COUNTER NEXT TO THE DISHMACHINE, 5 MOUSE DROPPINGS ON THE FLOOR AND FLOOR MIXERS UNDERNEATH THE DISHMACHINE, 10 MOUSE DROPPINGS UNDERNEATH THE CASH REGISTER AND 5 MOUSE DROPPINGS ON THE FLOOR NEXT TO THE CASH REGISTER, 30 MOUSE DROPPINGS ON THE FLOOR OF ROOM 420, 40 MOUSE DROPPINGS ON THE SHELVING UNITS OF THE 4TH FLOOR STORAGE ROOM, 20 MOUSE DROPPINGS ON THE FLOOR OF THE 4TH FLOOR JANITOR'S CLOSET NEXT TO THE WOMEN'S RESTROOM, 5 MOUSE DROPPINGS ON THE FLOOR OF ROOM 416, 5 MOUSE DROPPINGS ON THE FLOOR OF ROOM 410, 30 MOUSE DROPPINGS ON THE FLOOR OF THE 4TH FLOOR JANITOR'S CLOSET NEXT TO THE MEN'S WASHROOM, 5 MOUSE DROPPINGS ON THE FLOOR OF ROOM 306. ADDITIONAL PEST CONTROL SERVICE IS NEEDED TO MINIMIZE OR ELIMINATE THE PEST ACTIVITY. MUST CLEAN AND REMOVE ALL RODENT DROPPINGS FROM THE CLASSROOMS THROUGHOUT. CRITICAL VIOLATION 7-38-020.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- CLEAN THE FLOOR THROUGHOUT THE SCHOOL TO ELIMINATE FOOD DEBRIS AND PEST HARBORAGE. FLOOR IN THE BASEMENT MUST BE SMOOTH AND EASILY CLEANABLE.
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- SEAL ALL OPENINGS IN THE WALLS OF THE CLASSROOMS.
- 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
- REMOVE THE NON-WORKING DISHWASHING MACHINE AND PIZZA STOVE IN THE FOOD PREP AREAS TO ELIMINATE PEST HARBORAGE CONDITIONS.
- 13. NO EVIDENCE OF RODENT OR INSECT INFESTATION, NO BIRDS, TURTLES OR OTHER ANIMALS
- Canvass Re-Inspection
4 infractions
- 13. NO EVIDENCE OF RODENT OR INSECT INFESTATION, NO BIRDS, TURTLES OR OTHER ANIMALS
- STILL OBSERVED EVIDENCE OF RODENT INFESTATION THROUGHOUT THE CLASSROOMS. OBSERVED THE FOLLOWING AREAS IN ROOM 314 WITH RODENT DROPPINGS: 5 MOUSE DROPPINGS IN THE BACK CAVITY OF THE REFRIGERATOR, 5 DROPPINGS BEHIND THE CABINET, 40 DROPPINGS BEHIND THE SHELVING UNIT AND UNDER THE UNUSED HANDSINK. OBSERVED THE FOLLOWING AREAS WITH MOUSE DROPPINGS: ROOM 212 HAD 50 DROPPINGS ON THE FLOOR ALONG THE WALLS, ROOM 209 HAD 20 DROPPINGS ON THE FLOOR UNDER THE DESK AND AROUND THE CORNERS, ROOM 210 HAD 20 DROPPINGS ON THE FLOOR AGAINST THE WALLS AND CORNERS, ROOM 108 HAD 10 DROPPINGS ON THE TEACHER'S DESK AND 10 DROPPINGS ON THE CABINET NEXT TO THE DOOR, 20 DROPPINGS ON THE FLOOR OF THE BASEMENT STORAGE AND MAIN ROOMS. ALSO, OBSERVED 10 LIVE ANTS ON THE FLOOR OF THE LUNCHROOM. ADDITIONAL PEST CONTROL SERVICE IS NEEDED TO MINIMIZE OR ELIMINATE THE PEST ACTIVITY. MUST CLEAN AND REMOVE ALL RODENT DROPPINGS FROM THE CLASSROOMS THROUGHOUT. CRITICAL VIOLATION 7-38-020.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- CLEAN THE FLOOR THROUGHOUT THE SCHOOL TO ELIMINATE FOOD DEBRIS AND PEST HARBORAGE. FLOOR IN THE BASEMENT MUST BE SMOOTH AND EASILY CLEANABLE.
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- MUST SEAL ALL OPENINGS IN THE WALLS OF THE CLASSROOMS, ESPECIALLY AROUND WALL ABSE IN ROOM 314 AND IN ROOM 314 WHERE THE PIPES GO INTO THE WALL.
- 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
- REMOVE THE NON-WORKING DISHWASHING MACHINE AND PIZZA STOVE IN THE FOOD PREP AREAS TO ELIMINATE PEST HARBORAGE CONDITIONS.
- 13. NO EVIDENCE OF RODENT OR INSECT INFESTATION, NO BIRDS, TURTLES OR OTHER ANIMALS
- Canvass
4 infractions
- 12. HAND WASHING FACILITIES: WITH SOAP AND SANITARY HAND DRYING DEVICES, CONVENIENT AND ACCESSIBLE TO FOOD PREP AREA
- OBSERVED BROKEN SOAP DISPENSERS IN THE FOLLOWING STUDENT WASHROOMS: 4TH FLOOR GIRL'S, 3RD FLOOR BOY'S AND GIRL'S. ENGINEER INSTRUCTED TO LOCK DOORS AND NOT ALLOW STUDENTS TO USE WASHROOMS UNTIL SOAP DISPENSERS HAVE BEEN INSTALLED. ENGINEER INSTALLED THE SOAP DISPENSERS DURING THE INSPECTION. CRITICAL VIOLATION 7-38-030.
- 13. NO EVIDENCE OF RODENT OR INSECT INFESTATION, NO BIRDS, TURTLES OR OTHER ANIMALS
- OBSERVED EVIDENCE OF A RODENT INFESTATION THROUGHOUT THE SCHOOL. OBSERVED THE FOLLOWING AREAS WITH MOUSE DROPPINGS (ALL NUMBERS ARE APPROXIMATIONS): 50 DROPPINGS ON THE FLOOR UNDER THE OLD DISHWASHING MACHINE, 10 DROPPINGS ON THE FLOOR BEHIND THE OVEN AND STOVE, 10 DROPPINGS ON THE OUTSIDE BOTTOM LEDGE OF THE HOT HOLDING UNIT, 20 DROPPINGS ON THE FLOOR BEHIND THE GREASE TRAPS OF THE 3 COMPARTMENT SINKS, 40 DROPPINGS ON THE FLOOR AT THE WALL OF THE FOOD SERVICE LINE, 100 DROPPINGS ALONG THE BOTTOM METAL EDGES OF THE STEAM TABLE AND FLOOR UNDERNEATH THE STEAM TABLE, 20 DROPPINGS ON THE FLOOR UNDER THE MILK COOLER, 20 DROPPINGS INSIDE THE FAN UNIT OF THE TROPICANA JUICE COOLER, 50 DROPPINGS ON THE FLOOR ALONG THE WALLS OF THE FACULTY LUNCH ROOM, 15 DROPPINGS ON THE FLOOR IN THE CORNER OF THE LUNCH ROOM, 50 DROPPINGS ON THE FLOOR BEHIND THE UNUSED MILK COOLER IN THE LUNCH ROOM, 50 DROPPINGS ON THE FLOOR BEHIND THE TABLE AND LADDER AGAINST THE WALL IN THE LUNCH ROOM, 10 DROPPINGS ON THE TABLE WITH THE MICROWAVE IN THE LUNCH ROOM, 50 DROPPINGS ON THE FLOOR IN ROOM 314 BEHIND THE CABINET AND IN THE SMALL REFRIGERATOR FAN UNIT, 20 DROPPINGS ON THE FLOOR IN ROOM 325 NEAR THE WOOD SHELVING UNIT, 20 DROPPINGS ON THE FLOOR OF THE BASEMENT STORAGE AND MAIN ROOMS. ALSO, APPROXIMATELY 50 LIVE ANTS WERE OBSERVED ON THE FLOOR OF THE LUNCH ROOM, MANAGEMENT INSTRUCTED TO CLEAN AND REMOVE DROPPINGS AND LIVE ANTS FROM THE AFFECTED AREAS AND CLEAN AND SANITIZE. ADDITIONAL PEST CONTROL SERVICE IS NEEDED TO MINIMIZE OR ELIMINATE THE PEST ACTIVITY. CRITICAL VIOLATION 7-38-020.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- CLEAN THE FLOOR THROUGHOUT THE SCHOOL TO ELIMINATE FOOD DEBRIS AND PEST HARBORAGE. FLOOR IN THE BASEMENT MUST BE SMOOTH AND EASILY CLEANABLE.
- 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
- REMOVE THE NON-WORKING DISHWASHING MACHINE AND PIZZA STOVE IN THE FOOD PREP AREAS TO ELIMINATE PEST HARBORAGE CONDITIONS.
- 12. HAND WASHING FACILITIES: WITH SOAP AND SANITARY HAND DRYING DEVICES, CONVENIENT AND ACCESSIBLE TO FOOD PREP AREA
- Canvass
3 infractions
- 33. FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
- NOTED ICE BUILD UP AROUND THE AIR/VENT UNIT INSIDE THE WALK IN COOLER. MUST REMOVE THE ICE AND MAINTAIN THE VENT.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- FLOORS NEED CLEANING ALONG THE WALL BASE AND IN CORNERS TO REMOVE DEBRIS.
- 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
- NOTED MISSING LIGHT SHIELDS INSIDE THE FRONT WALK IN COOLERS. MUST PROVIDE AND MAINTAIN.
- 33. FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
- Canvass
5 infractions
- 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
- FOUND RUSTY STORAGE RACKS IN THE WALKIN COOLER. INSTRUCTED TO REMOVE THE RUST AND PAINT THEM WITH NON TOXIC PAINT. RUSTY GREASE TRAP UNDER THE 3-COMPARTMENT SINK SOUTH SIDE OF THE KITCHEN. MUST REMOVE THE RUST AND PAINT.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- MUST CLEAN THE FLOOR UNDER BEHIND THE HEAVY EQUIPMENT IN THE DISH MACHINE ROOM AND IN THE STORE ROOM.CLEAN FLOORS IN UTILITY CLOSETS TOO.
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- CEILINGS IN HALLWAYS ON 1ST, 2ND AND 3RD FLOORS HAVE PEELING PAINT THROUGHOUT. INSTRUCTED TO REMOVE THE PEELIND PAINT AND PAINT THEM. FOUND DAMAGED WALLS THROUGHOUT THE WHOLE SCHOOL. MUST REPAIR THEM.
- 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
- FOUND THE WASTE WATER PIPES BY THE CEILING IN THE BOILER ROOM WITH HOLES IN THEM. THE LARGE HOT WATER TANK IS RUSTING OUT ON THE BOTTOM. MUST REPAIR OR REPLACE THEM.
- 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
- MUST ORGANIZE AND MAINTAIN ALL UTILITY CLOSETS. FAN ROOM HAS CLUTTER OLD UNUSED EQUIPMENT ECT. MUST REMOVE THE UNNECESSARY ARTICLES CLEAN AND ORGNIZE SO NO INSECT OR RODENT HARBORAGE.
- 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
- Canvass
3 infractions
- 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
- MUST SEAL/REPAINT RUSTY WIRE SHELVING IN WALK-IN COOLER
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- MUST REMOVE/REPAINT PEELING PAINT VARIOUS AREAS OF CEILINGS IN HALLWAYS ON 1ST, 2ND AND 3RD FLOORS AREAS
- 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
- MUST CLEAN LIGHT SHIELD BY DISH MACHINE AREA, REMOVE ALL DIRT AND DEBRI
- 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
- Canvass
4 infractions
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
- The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair. CLEAN FLOORS IN UTILITY CLOSETS AND MAINTAIN. CLEAN IN STUDENT WASHROOMS.
- 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
- The walls and ceilings shall be in good repair and easily cleaned. PREVIOUS VIOLATIONS FROM OCT. 2009 WERE CORRECTED. MUST REMOVE PAPER FROM CEILING OF BOYS WASHROOM ON SECOND FLOOR. VARIOUS AREAS OF CEILINGS IN HALLWAYS ON 1ST, 2ND AND 3RD FLOORS HAVE PEELING PAINT; REMOVE AND REPAINT.
- 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
- PREVIOUS VIOLATIONS FROM OCT 2009 WERE CORRECTED. Ventilation: All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health. MUST CORRECT THE FOLLOWING: 4TH FLOOR BOYS WASHROOM HAS ONE SINK WITH NO RUNNING WATER; PROVIDE. 2ND FLOOR BOYS WASHROOM HAS ONE TOILET SEAT THAT IS LOOSE FROM HINGE; REATTACH. 3RD FLOOR GIRLS WASHROOM HAS ONE SINK THAT IS LOOSE FROM THE WALL; REATTACH TO WALL.
- 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
- MUST ORGANIZE AND MAINTAIN ALL UTILITY CLOSETS.
- 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED