17311 69 Avenue NW - Swimming Pool
17311 69 Avenue NW Edmonton AB T5T 3S3 · Aquatic Facility
Inspection summary
17311 69 Avenue NW - Swimming Pool has been inspected 8 times by Alberta Health Services (Environmental Public Health) since July 22, 2024. The most recent inspection, on February 5, 2026, recorded 2 infractions.
3 of 8 inspections on record found no infractions at all. In the past 12 months there was 1 inspection with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 5 times across 5 separate inspections, most recently on February 5, 2026. For example:
Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 2 times on July 22, 2024. For example:
Is the chemical quality of the water in this pool satisfactory (Critical)?
Food safety training and certificationLower risk
Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.
Recorded once on February 5, 2026. For example:
Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
8 inspections
- Demand Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Observed water weeping from the front bottom part of the horizontal sand filter. Current filter is to be replaced. Facility has requested quotes from pool service providers and will determine replacement options once those are submitted. Confirmed onsite the following:- Pool volume is 99000 Gal- To achieve a 6 hour turnover the pool must run at no less than 275 GPM.* Current filter area is unable to accommodate 275 GPM (filtration rate is 18.3 GPM/sq ft and exceeds the manufactures maximum rate). The minimum filter size required would be 18.3 Sq Ft.- Pool service provider adjusted valving to confirm maximum flow through the system and noted the pump was able to achieve up to 320 GPM. Pool pump is B&G E1532 3BD 15Hp 1800 RPM. Pump does not match the anti-entrapment compliance plan.* Flow meter has been installed in a small section of SCH40 plumbing between SCH80 piping. Pool service provider will reach out to flow meter manufacture to confirm if the installation of the flow meter is adequate to properly measure the maximum flow of the system. Current flow meter installed can be moved to another location as it can be used to read flow in 4" pipe in both SCH40 & SCH80 pipe.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The anti-entrapment compliance plan has not been updated to reflect the pump currently installed. Update the anti-entrapment plan to reflect the pump changes.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
0 infractions
- Demand Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The filtration rate was observed to be 16.02. Please adjust flow rate to align with manufacturers recommendation of 229GPM for the filters. 207-229GPM optimal is required to achieve this.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample received on 25/03/2025 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow rate: 245GPMFiltration rate was 16.01gpm/ft2. Maximum flow rate of 229GPM according to the manufacturer's specifications for the filter. 207-229GPM optimal to achieve the required filtration rate.Adjust the flow rate
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Free Chlorine: 0.84ppmORP: 678mV (Set Point: 710mV)Pool was closed voluntarily by the pool operator.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total Alkalinity: 54ppm
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow rate: 245GPMFiltration rate was 16.01gpm/ft2. Maximum flow rate of 229GPM according to the manufacturer's specifications for the filter. 207-229GPM optimal to achieve the required filtration rate.Adjust the flow rate
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
Nearby inspected facilities
- 17311 69 Avenue NW - Pool Premise Common Area
17311 69 Avenue NW Edmonton AB T5T 3S3
3 inspections
- Aoartistry / The Glam Salon and Spa
101 - 17319 69 Avenue NW Edmonton AB T5T 3S7
1 inspection
- Mini Max Convenience Store - Food Store
108 - 17319 69 Avenue NW Edmonton AB T5T 3S7
2 inspections
- Shiba Eatery - Events
320 - 17404 64 Avenue NW Edmonton AB T5T 6X4
1 inspection
- Black Market Tattoo - Events
6713 177 Street NW Edmonton AB T5T 4K3
1 inspection
- Black Market Tattoo
6713 177 Street NW Edmonton AB T5T 4K3
2 inspections
- Wonder World Callingwood Child Care Centre - Kitchen
6703 177 Street NW Edmonton AB T5T 4K3
4 inspections
- Wonder World Callingwood Child Care Centre - Daycare/OSC
6703 177 Street NW Edmonton AB T5T 4K3
6 inspections