Skip to content
Loading map…

8930 Jasper Avenue NW - Swimming Pool

150 - 8930 Jasper Avenue NW Edmonton AB T5H 4E9 · Aquatic Facility

9 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample result collected on 08/08/2025 [25EN-220E00190] was unsatisfactory: HPC 1230 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  3. Demand Inspection

    0 infractions

  4. Risk Management Inspection

    0 infractions

  5. Risk Management Inspection

    0 infractions

  6. Risk Management Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • There was damage to a ceiling tile directly above the pool basin.There was a ceiling light hanging from its wires directly above the pool basin.
  7. Risk Management Inspection

    3 infractions

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • There was damage to a ceiling tile directly above the pool basin.There was a ceiling light hanging from its wires directly above the pool basin.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The main drain covers have expired.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An updated anti-entrapment plan is required to be provided to this office.
  8. Monitoring Inspection

    0 infractions

  9. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample result submitted on 2024-03-04 [Accession #: WE-24-0021233] was unsatisfactory: HPC 18390 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Automated controller results are not consistent with manual tests. Manual pH levels were 6.6; controller pH levels 7.16. A difference of +/- 0.2 is considered acceptable. Continue to monitor manual and controller pH readings. Please take necessary actions if needed. Rainier indicated that the probes/sensor's have been cleaned and/or changed. Calibration may be required. Contact your pool service provider for assistance if needed.