9908 114 Street NW - Swimming Pool

9908 114 Street NW Edmonton AB T5K 1R1 · Aquatic Facility

Inspection summary

9908 114 Street NW - Swimming Pool has been inspected 6 times by Alberta Health Services (Environmental Public Health) since July 15, 2024. The most recent inspection, on November 17, 2025, recorded 1 infraction.

None of the 6 inspections on record were free of infractions. In the past 12 months there were 2 inspections with 3 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 7 times across 6 separate inspections, most recently on November 17, 2025. For example: Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

6 inspections

  1. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Noted that the ORP reading of 695 was below the set point of 740. Onsite manager noted that there are controller repairs ongoing, and the company will be coming in on Monday 18 2025.
  2. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on 6 Nov 2025 was unsatisfactory: HPC 2120 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Noted that the ORP reading of 695 was below the set point of 740. Onsite manager noted that there are controller repairs ongoing, and the company will be coming in on Monday 18 2025.
  3. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Noted that the ORP reading of 695 was below the set point of 740. Onsite manager noted that there are controller repairs ongoing, and the company will be coming in on Monday 18 2025.
  4. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Noted that the ORP reading was above the set point to maintain the required free chlorine in the pool. Onsite manager noted that there is controller repairs required to address concerns with the salt cell recognizing flow of the system. Quote has been sent to the board for approval. Ensure controller is repaired to maintain free chlorine in the basin.
  5. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. Noted that the ORP reading was above the set point to maintain the required free chlorine in the pool. Onsite manager noted that there is controller repairs required to address concerns with the salt cell recognizing flow of the system. Quote has been sent to the board for approval. Ensure controller is repaired to maintain free chlorine in the basin.2. Scum/biofilm noted on the inside back of the skimmer pots. Clean and remove biofilm. Ensure skimmer pots are cleaned weekly.
  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on 11 July 2024 was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.