Best Western Plus Edmonton Airport - Whirlpool

5705 50 Street Leduc AB T9E 6Z8 · Aquatic Facility

14 inspections

  1. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • pseudomonas aeringosa was isolated in the sample collected on July 7th.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The heterotrophic plate count was 3,200 for the sample collected on July 7th.
  2. Risk Management Inspection

    0 infractions

  3. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample results for sample collected Feb 17th:-Pseudomonas aeruginosa: Isolated
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Whirlpool sample results for the sample that was collected on Feb 17th:- HPC: >57,000
  4. Risk Management Inspection

    0 infractions

  5. Risk Management Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The chlorine test kit was unable to provide a reading because the chlorine concentration was above the measurable range. The automated controller reading for the chlorine was 8.26. The operator was in the process of backwashing.
  6. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The free available chlorine was 0.9 on the pool kit. The automatic controller had its alert sign flashing and was rebooted at the time of inspection.
  7. Demand Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Pool alkalinity was observed at 57ppm. Operator is advised to keep alkalinity within 60-180ppm range.
  8. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Pool alkalinity was observed at 57ppm. Operator is advised to keep alkalinity within 60-180ppm range.
  9. Risk Management Inspection

    1 infraction

    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • *** Pool permit not observed.Ensure that the pool permit is displayed July 04, 2024: Pool permit was still not observed. Please ensure your pool permit is displayed at the facility.
  10. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined Chlorine was measured to be at 1.69ppm.Please ensure combined chlorine is maintained at the lowest possible level.
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • *** Pool permit not observed.Ensure that the pool permit is displayed July 04, 2024: Pool permit was still not observed. Please ensure your pool permit is displayed at the facility.
  11. Risk Management Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample # 2626250 submitted on March 19, 2024 revealed HPC level 770 CFU per ml.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity is 30 ppm.
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • *** Pool permit not observed.Ensure that the pool permit is displayed
  12. Risk Management Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample # 2626250 submitted on March 19, 2024 revealed HPC level 770 CFU per ml.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity is 30 ppm.
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • *** Pool permit not observed.Ensure that the pool permit is displayed
  13. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity is 30 ppm.
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • *** Pool permit not observed.Ensure that the pool permit is displayed
  14. Monitoring Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • A water sample submitted on March 27 had Pseudomonas and >57000 HPC. Treatment requirements were discussed with the operator. Recommend Filters be backwashed, shock chlorinate pool for about 4-6 hours, drain and clean pool basin, refill, balance pool chemistry and resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity is 30 ppm.
    • 11. Does the facility have a valid permit and does the facility operate in compliance with the conditions of that permit?
      • *** Pool permit not observed.Ensure that the pool permit is displayed
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An appropriate anti-entrapment plan has not been established. The assessment forms and information package to complete the assessment was given to the operator. The operator was directed to immediately complete the anti-entrapment assessment.