Days Inn Calgary South - Whirlpool

3828 Macleod Trail SE Calgary AB T2G 2R2 · Aquatic Facility

14 inspections

  1. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. The water sample collected on June 18, 2026 was present for pseudomonas. Facility informed to treat, drain, and submit a re-sample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • **OUTSTANDING**1. The combined chlorine measured 2.07ppm. **February 23, 2026: unable to measure the amount of combined chlorine. The total chlorine amount was greater than 6.00ppm and the free chlorine measured 3.57ppm, which may indicate that the combined chlorine was greater than 2.43ppm.COMPLETE THE FOLLOWING:1. Keep combined chlorine as low as possible. It is recommended to maintain combined chlorine below 1.00ppm.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • **OUTSTANDING**1. The anti-entrapment plans for the whirlpool are inaccurate and missing information.**February 23, 2026: facility has their pool contractor working on the plans. COMPLETE THE FOLLOWING:1. Please review the anti-entrapment plans and ensure they are accurate and complete. Include supporting documents such as certificates of compliance, photos of flow metres, photos of drain covers, sump drawings, etc.
  2. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. Pseudomonas aeruginosa was isolated in the water sample collected on June 3, 2026.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • **OUTSTANDING**1. The combined chlorine measured 2.07ppm. **February 23, 2026: unable to measure the amount of combined chlorine. The total chlorine amount was greater than 6.00ppm and the free chlorine measured 3.57ppm, which may indicate that the combined chlorine was greater than 2.43ppm.COMPLETE THE FOLLOWING:1. Keep combined chlorine as low as possible. It is recommended to maintain combined chlorine below 1.00ppm.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • **OUTSTANDING**1. The anti-entrapment plans for the whirlpool are inaccurate and missing information.**February 23, 2026: facility has their pool contractor working on the plans. COMPLETE THE FOLLOWING:1. Please review the anti-entrapment plans and ensure they are accurate and complete. Include supporting documents such as certificates of compliance, photos of flow metres, photos of drain covers, sump drawings, etc.
  3. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • **OUTSTANDING**1. The combined chlorine measured 2.07ppm. **February 23, 2026: unable to measure the amount of combined chlorine. The total chlorine amount was greater than 6.00ppm and the free chlorine measured 3.57ppm, which may indicate that the combined chlorine was greater than 2.43ppm.COMPLETE THE FOLLOWING:1. Keep combined chlorine as low as possible. It is recommended to maintain combined chlorine below 1.00ppm.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • **OUTSTANDING**1. The anti-entrapment plans for the whirlpool are inaccurate and missing information.**February 23, 2026: facility has their pool contractor working on the plans. COMPLETE THE FOLLOWING:1. Please review the anti-entrapment plans and ensure they are accurate and complete. Include supporting documents such as certificates of compliance, photos of flow metres, photos of drain covers, sump drawings, etc.
  4. Monitoring Inspection

    5 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • 1. The combined chlorine measured 2.07ppm. COMPLETE THE FOLLOWING:1. Keep combined chlorine as low as possible. It is recommended to maintain combined chlorine below 1.00ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1. The main drain valve was opened at 100%.2. The flow metre for the jet pump was not operational.3. Information on filter regarding filter model and filter area not specified on equipment.COMPLETE THE FOLLOWING:1. Adjust the main drain valve to be opened no more than 30% to increase flow through the skimmer, as the top portion of the pool water containers the greatest amount of contaminants.2. Replace the jet pump flow metre.3. Confirm make, model and filter area in order to calculate filtration rate and maximum flow rate.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • 1. One of the screws on the west floor drain is discoloured.COMPLETE THE FOLLOWING:1. Replace the screw.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • 1. Water chemistry tests were not being checked and recorded daily. COMPLETE THE FOLLOWING:1. Water chemistry must be checked at least once per day, and tests must be recorded in the chemistry log sheet.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • 1. The anti-entrapment plans for the whirlpool are inaccurate and missing information.COMPLETE THE FOLLOWING:1. Please review the anti-entrapment plans and ensure they are accurate and complete. Include supporting documents such as certificates of compliance, photos of flow metres, photos of drain covers, sump drawings, etc.
  5. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • 1. Pseudomonas aeruginosa isolated in water sample collected on December 4, 2025.
  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. October 23, 2025 sample not tested, because water sample bottle received empty.
  7. Monitoring Inspection

    0 infractions

  8. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The sample was received more than 24 hours after collection.Resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • There are various policies and plans missing from the premise. Please refer to the Pool Standards for more information.
  9. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The lab could not process the sample that was submitted on July 25, 2024 as the date/time of collection was later than the date/time of receipt.Resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • There are various policies and plans missing from the premise. Please refer to the Pool Standards for more information.
  10. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The sample collected on June 6, 2024 has pseudomonas present.Clean the whirlpool, treat and rebalance the whirlpool before submitting a resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Pool water sample collected on June 20, 2024, was not processed because there was no identification number on the bottle.-Please resample and ensure to follow the proper sampling procedure.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • There are various policies and plans missing from the premise. Please refer to the Pool Standards for more information.
  11. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The sample collected on June 6, 2024 has pseudomonas present.Clean the whirlpool, treat and rebalance the whirlpool before submitting a resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • There are various policies and plans missing from the premise. Please refer to the Pool Standards for more information.
  12. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The sample collected on March 21, 2024 has total coliforms present.Clean the whirlpool, treat and rebalance the whirlpool before submitting a resample.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • There are various policies and plans missing from the premise. Please refer to the Pool Standards for more information.
  13. Monitoring Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • There are various policies and plans missing from the premise. Please refer to the Pool Standards for more information.
  14. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The sample collected on November 23, 2023 has pseudomonas present.Clean the basin, treat, and send in a resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on February 8, 2023 at 8:18am was not processed as it was received more than 24 hours after collection.-Resample
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • There are various policies and plans missing from the premise. Please refer to the Pool Standards for more information.