Skip to content
Loading map…

Dr. Lander Memorial Pool - Pool

207 Main Street NE Diamond Valley AB T0L 2A0 · Aquatic Facility

18 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • There was an accumulation of dirt and debris noted throughout the bottom of the pool.- Debris to be cleaned.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The bacterial water sample taken on July 28, 2025 had an HPC result of 180 CFU/mL.- Pool chemistry to be balanced and a satisfactory resample submitted.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The bacterial water sample submitted on July 14, 2025 was present for total coliform bacteria.- A satisfactory bacterial water sample is required. Chemical treatment and rebalancing of pool chemistry is recommended prior to submitting a resample.
  7. Risk Management Inspection

    0 infractions

  8. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity of the pool water measured between 9ppm and 36ppm at 3 different points of the pool basin.- Alkalinity to be between 60ppm-180ppm
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The most recent bacteriological water sample indicated a heterotrophic plate count of 440 CFU/100mL.
  11. Risk Management Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Bacterial water sample taken on July 8, 2024 had an HPC count of 110 CFU/ mL- Pool to be chemically balanced and satisfactory resample to be submitted.
  13. Demand Inspection

    0 infractions

  14. Risk Management Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH of the pool measured to be 7.81.- The pH cannot exceed 7.6. No staff or members of the public were present during the inspection. Staff added sodium bisulfate to the pool during the inspection. The pH measured 7.3 by the end of the inspection. Corrected during inspection.
  15. Monitoring Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • There was an accumulation of debris noted at the bottom of the pool on the northeast corner and south deep end.- Debris to be cleaned.
  16. Risk Management Inspection

    0 infractions

  17. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The most recent bacteriological water sample indicated a HPC count above 100 CFU/100mL.
  18. Demand Inspection

    0 infractions