Edgecliffe Estates - Whirlpool

OFFICE - 3400 Edenwold Heights NW Calgary AB T3A 3Y8 · Aquatic Facility

12 inspections

  1. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on 11/05/2026 was rejected due to time of collection not indicated on the form.Resample
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The Filtration rate was recorded at 18.5 USG ft2.The filtration rate must be less than 12.5 USG/M/FT2 for whirlpools
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The anti-entrapment plan installed expired in March 2022.Install and submit an updated anti-entrapment plan.
  2. Monitoring Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on 19/08/2025 tested positive for pseudomonas aeruginosa.Treat and resample
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The Filtration rate was recorded at 18.5 USG ft2.The filtration rate must be less than 12.5 USG/M/FT2 for whirlpools
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The anti-entrapment plan installed expired in March 2022.Install and submit an updated anti-entrapment plan.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Repeat violation:Water sample collected on 22/07/2025 tested positive for Pseudomonas aeruginosa.Recurring violation:The water sample collected on 18/07/2025, tested positive for pseudomonas aeruginosa.Close the hot tub.Repeat violation:The water sample collected on 14/07/2025, tested positive for Pseudomonas aeruginosa.Treat and resample.Previous violation:The water sample collected on 30/06/2025, tested positive for Pseudomonas aeruginosa.Treat and resample.
  5. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Recurring violation:The water sample collected on 18/07/2025, tested positive for pseudomonas aeruginosa.Close the hot tub.Repeat violation:The water sample collected on 14/07/2025, tested positive for Pseudomonas aeruginosa.Treat and resample.Previous violation:The water sample collected on 30/06/2025, tested positive for Pseudomonas aeruginosa.Treat and resample.
  6. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on 14/07/2025, tested positive for Pseudomonas aeruginosa.Treat and resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on 14/07/2025, had a HPC of 1230 CFC/mL.Treat and resample.
  7. Risk Management Inspection

    0 infractions

  8. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample result rejected. The sample was received more than 24 hours after collection.
  9. Risk Management Inspection

    0 infractions

  10. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow meter after the filter was not functional. Hence turnover rate and filtration rate could not be determined. Replace the dysfunctional flow meter.
  11. Risk Management Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was isolated per 100mL.-Please treat the hot tub following AHS unsatisfactory water sample for Pseudomonas aeruginosa.