Encore Medical Rejuvenation
20164 Lessard Road NW Edmonton AB T6M 0T9 · Personal Services
3 inspections
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- No written procedures for skin cleansing prior to services and antiseptic use were available.
- 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
- Sterility assurance documentation for sterile equipment was not retained with the clients' records. Ensure that sterility assurance documentation for all critical equipment used during services is retained with clients' forms.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- Demand Inspection
6 infractions
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- No written procedures for skin cleansing prior to services and antiseptic use were available.
- 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
- Unacceptable antiseptic product (alcohol-based) was used for skin preparation: no DIN or NPN was available. Stanhexidine antiseptic was also available (acceptable). Please ensure that only approved antiseptic products are used.
- 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
- Sterility assurance documentation for sterile equipment was not retained with the clients' records. Ensure that sterility assurance documentation for all critical equipment used during services is retained with clients' forms.
- 20. Is reusable equipment disinfected properly?
- No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
- 20. Is reusable equipment disinfected properly?
- No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
- 26. Are cosmetic products appropriate for their intended use and being handled properly?
- Manufacturer's instructions for use of cosmetic products were not being followed: both bacteriostatic and preservative-free saline solutions were being used for reconstitution, while manufacturer requires a preservative-free saline be used. Ensure that only preservative-free saline is used.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?