Glen Allan Recreation Complex - Whirlpool and Sauna
199 Georgian Way Sherwood Park AB T8A 2W9 · Aquatic Facility
13 inspections
- Monitoring Inspection
0 infractions
- Demand Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- A heterotrophic plate count of 6,480 was received from water sample report.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- A heterotrophic plate count of 6,480 was received from water sample report.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- total coliforms present.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Unsatisfactory Lab Test Result: - Presence of total coliforms.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow rate at the time of inspection was 103 USG/min. Turnover period with 2,260 USG pool volume = 22minutes. Flow rate was adjusted to 110 USG/min during inspection to achieve 20 minutes turnover period.* Please note that a minimum of 110 USG/min flow rate is required to maintain the required turnover period of not more than 20minutes.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water result submitted for the whirlpool on July 02, 2025, was unsatisfactory.Unsatisfactory Lab Test Result: ** Pseudomonas aeruginosa: ISOLATED
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Improve on floor sanitation in the mechanical room due to chemical spillage and staining below equipment.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?